Smart Intelligent Wcq2g ATS Automatic Transfer Switch 1p 2p 3p 4p

WCQ2G series MCB is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Social focus:

WCQ2G Moulded case circuit breaker

WCQ2G is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

WCQ2G series double power supplies automatic transfer switch (ATS) applies to AC50Hz, rated operation voltage 400V, rated operation current 16A to 2000A, to two circuits power supply of emergency power supply system. It can be set as manual of the mutual transfer between frequent-use and backup power supply, as circuit controlling switch of control, signal, and interlock functions. Some types of the product have communication ports to make it realisable of remote control and unattended substation to the user. Itapplies to residence community, hospital, mall, airport, etc.,

The ATS meets standards IEC/EN60947 and GB/T14048.11.

Model and meaning

Working environment

The WCQ2G automatic transfer switch works reliably under the following conditions:
Altitude not exceeding 2000 meters
Ambient temperature not higher than 40℃,not lower than-5℃,relative humidity not more than 95%.
No explosion hazardous medium environment
No rain or snow attack environment

Note:If the switch is expected to be used in conditions where the ambient air temperatureis higher than+40℃or lower than -5~-45,the user should explain to the manufacturer.

KEY INFORMATION

WCQ2G

Pole  3P, 4P
Voltage  AC230V/400V
Icm 8KA-26KA
Inm(A) 100,160,250,630
In(A)  16-630

MAIN TECHNICAL DATA

Conventional thermal current Ith (A) 100 160 250 630 1600
Rated current In (A) 20 40 63 80 125 160 200 250 400 630 800 1000 1250 1600
Rated insulation voltage Ui (V) 690 690 690 690 690 690 690 690 690 690 690 690 690 690
Dielectric strength (V) 5000 5000 5000 5000 5000 5000 5000 5000 8000 8000 10000 10000 10000 10000
Rated impulse withstand voltage Uimp (kV) mounting catagory (IV) 8 8 8 8 8 8 8 8 12 12 12 12 12 12
Rated service current Ie (A) 400V AC-31 20 40 63 80 125 160 200 250 400 630 800 1000 1250 1600
AC-33 20 40 63 80 125 160 200 250 400 630 800 1000 1250 1600
AC-35 20 32 40 63 80 125 160 200 250 400 630 800 1000 1250
230V DC-31 20 40 63 80 125 160 200 250 400 630 800 1000 1250 1600
DC-33 20 40 63 80 125 160 200 250 400 630 800 1000 1250 1600
DC-35 20 32 40 63 80 125 160 200 250 400 630 800 1000 1250
Power of motor P (400V) (kW) 10 25 25 30 63 80 100 132 220 280 450 560 560 560
Rated short time withstand current Icw (kA Rms) 0.1S/1S 3/2.0 4/4.2 5/2.5 9/5 20/10 20/10 25/12 25/12 40/20 50/25 90/50 90/50 90/50 90/50
Rated breaking capacity (kA Rms) AC35 400V 160 320 500 640 1000 1000 1600 1600 3200 3200 8000 8000 8000 8000
Rated connecting capacity (kA Rms) AC35 400V 200 400 630 800 1250 1250 2000 2000 4000 4000 10000 10000 10000 10000
Rated short circuit breaking capacity Icm (kA peak value) 8 8 10 10 12 12 17 17 30 30 50 50 50 50
Mechanical life (circulation operation times) 100000 100000 100000 100000 100000 100000 100000 100000 5500 5500 4000 4000 4000 3000
Electrical life Cos Φ = 0.95 AC31 2500 2500 2500 1500 1500 1500 1500 1500 750 750 600 600 600 450
Cos Φ = 0.65 AC33 1500 1500 1500 1000 1000 1000 1000 1000 500 500 400 400 400 300
Cos Φ = 0.35 AC35 750 750 750 500 500 500 500 500 250 250 200 200 200 150
Transfer time I-O-II or II-O-I (s) 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.2 1.2 1.2 1.2 1.2
I-O or II-O-I (s) 0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.7 0.8 0.8 0.8 0.8 0.8 0.8
Motor energy consumption 24V (DC) (w) 40 40 40 75 75 75 75 75 90 90 120 120 120 120
230V (AC) (w) 40 40 40 75 75 75 75 75 90 90 120 120 120 120
Operation torque (Nm) 12 12 12 19 19 19 26 26 39 39 39 39 39 60
Weight (kg) Three poles 7.2 7.2 7.2 8 8 10 10 22 22 22 34
Four poles 4.2 4.3 4.4 7.5 7.5 7.5 9 9 11 11 28 28 28 40

OVERALL AND MOUNTING DIMENSION(MM)

This topic is covered in more detail in Double Power Supplies Wcq2g Automatic Intelligent Type Changeover Switch 50Hz 400V Transfer Switch.

FREQUENTLY ASKED QUESTION (FAQ)

What makes this WCQ2G "smart/intelligent"? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The smart version adds an electronic controller that continuously monitors both sources, makes decisions based on programmable thresholds, and reports its status. This goes beyond a simple motorized changeover by offering self-diagnosis, adjustable parameters, and optional remote communication for unattended operation.

What does the LCD/status display show? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The display indicates which source is live, whether the load is on the main or backup supply, voltage/frequency values, and any fault or alarm conditions. It lets the operator confirm the transfer state at a glance without measuring each circuit manually.

Can I program voltage thresholds and time delays? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes. The controller is programmable, allowing you to set undervoltage/overvoltage trip levels, transfer delay, retransfer delay, and generator warm-up/cool-down timing. This lets you tailor behavior to the load and the tolerance of your backup source.

Does it support remote communication? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Select versions include communication ports for remote monitoring and control, which supports unattended substations and building management systems. Through these interfaces you can read source status, transfer events, and alarms from a central supervisory system.

How does it monitor main vs. backup source status? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The controller measures voltage (and frequency where applicable) on both inputs in real time. If one source drifts outside the configured band while the other is healthy, it initiates a controlled transfer according to the programmed logic and delays.

How does automatic changeover to the generator work? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

On main failure, the controller starts the generator via a relay output, waits until its output is stable, then closes the backup path. When the main supply is restored and remains stable for the retransfer delay, it transfers back and shuts the generator down after a cool-down period.

What pole configurations are available? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The smart WCQ2G is offered in 1P, 2P, 3P, and 4P versions. Single-phase loads use 1P or 2P, while three-phase installations choose 3P (without neutral switching) or 4P (with neutral switching) depending on the earthing arrangement.

How does manual override work? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

An emergency manual operation lets you operate the mechanism by hand for commissioning or in a power-loss control scenario. The device can also be set to manual mutual transfer between preferred and backup sources when automatic operation is not desired.

Where is this intelligent ATS typically installed? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is used in hospitals, commercial centers, airports, industrial plants, and residential communities where automatic, monitored backup power is required. It is especially suitable for installations that need remote supervision rather than a manned switchboard.

Which standards and certifications apply? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is built to IEC/EN 60947-6-1 and GB/T 14048.11 for transfer switching equipment. These standards define the ratings, interlock requirements, and endurance tests that ensure safe, reliable transfer between two supplies.

RELATED PROJECTS