Get quick appointment for technical support!

Get in Touch

JR36 Motor Protection Relay

Westhomes JR36 sealed electromagnetic thermal overload relay, miniature pin style with durable AC copper contacts, rated 0.1-140A and adjustable 9-95A, 3-phase stable structure, flexible mounting, robust long-distance control for industrial motors.

Social focus:

Westhomes JR36 Motor Protection Relay | Sealed Miniature Pin Design

Westhomes JR36 sealed electromagnetic thermal overload relay, miniature pin style with durable AC copper contacts, rated 0.1-140A and adjustable 9-95A, 3-phase stable structure, flexible mounting, robust long-distance control for industrial motors.

Westhomes JR36

The Westhomes JR36 sealed electromagnetic thermal overload relay is a professionally designed industrial protection component specifically designed for reliable remote motor control and comprehensive thermal overload protection. This miniature needle relay features a fully sealed electromagnet with stronger dust, moisture, and electrical interference resistance, making it fully adaptable to various industrial working environments.

Key Features:

Extra-Long Service Life & Low Upkeep: Crafted with wear-resistant industrial-grade materials and precision manufacturing, built for sustained durability, requiring only minimal routine maintenance to keep optimal performance.

Versatile Mounting Flexibility: Supports both screw mounting and standard DIN rail installation, with simple wiring and quick setup steps, adapting to different control cabinet layouts and installation demands.

Miniature Pin Type & Copper Contacts: Compact miniature size with standard pin interface saves installation space; premium AC copper contacts boost conductivity and contact stability for extended relay life.

Sealed Robust Construction: Fully sealed electromagnetic design with high-strength casing, resisting external damage and interference, delivering reliable long-distance switching and stable operation under heavy use.

Applications:

Harsh Environment Workshops

Equipment Retrofit & Replacement

Long-Distance Remote Control Systems

Setting Current Adjustment Range And Number

Model Current Adjus-
tment Range
Control Power(kW) Pluggable Contactor Short Circuit Protection
Fusegreed Heating Current
220V 380V 415V 440V 660V aM gG
JR28-09301d 0.1~0.16 CJX2-09~25 0.25 2
JR28-09302d 0.16~0.25 CJX2-09~25 0.5 2
JR28-09303d 0.25~0.40 CJX2-09~25 1 2
JR28-09304d 0.40~0.63 0.37 CJX2-09~25 1 2
JR28-09305d 0.63~1 0.55 CJX2-09~25 2 4
JR28-09306d 1~1.6 0.37 0.55 0.75 CJX2-09~25 2 4
JR28-09307d 1.6~2.5 0.37 0.55 0.75 1.1 1.5 CJX2-09~25 4 6
JR28-09308d 2.5~4 0.75 1.1 1.5 2.2 3 CJX2-09~25 6 10
JR28-09310d 4~6 1.1 2.2 2.2 2.2 4 CJX2-09~25 8 16
JR28-09312d 5.5~8 1.5 3 3.7 3.7 5.5 CJX2-09~25 12 20
JR28-09314d 7~10 2.2 4 4 4 7.5 CJX2-09~25 12 20
JR28-12316d 9~13 3 5.5 5.5 5.5 10 CJX2-09~25 16 25
JR28-18321d 12~18 4 7.5 9 9 15 CJX2-09~25 20 35
JR28-25322d 17~25 5.5 11 11 11 18.5 CJX2-09~25 25 50
JR28-32353d 23~32 7.5 15 15 15 22 CJX2-32 40 63
JR28-32355d 28~36 10 18.5 22 22 30 CJX2-32 40 80
JR28-40353d 23~32 7.5 15 15 15 22 CJX2-40~80 40 63
JR28-40355d 30~40 10 18.5 22 22 30 CJX2-40~80 40 80
JR28-50357d 37~50 11 22 25 25 37 CJX2-40~80 63 100
JR28-65359d 48~65 15 25 30 30 45 CJX2-40~80 63 100
JR28-65361d 55~70 18.5 30 37 37 55 CJX2-40~80 80 125
JR28-80363d 63~80 22 37 45 45 75 CJX2-40~80 80 125
JR28-140365d 80~104 30 45 55 55 75 CJX2-115~170 125 200
JR28-140367d 95~120 30 55 75 75 90 CJX2-115~170 125 224
JR28-140369d 110~140 37 63 75 75 110 CJX2-115~170 160 250

Shape Size And Installation Size

Shape Size And Installation Size

Packaging and delivery

Selling Units Single item

Lead time

Quantity (pieces) 1 – 100 > 100
Lead time (days) 15 To be negotiated

Key attributes

Theory AC
Power Source 50 Hz, 60 Hz
Terminal Shape Screw or rail installation
Contact Material CJX2
Place of Origin Zhejiang, China
Rated Current 0.1-140A
Size Miniature
Contact Load Low Power
Model Number JR28
Brand Name Westhomes

FREQUENTLY ASKED QUESTION (FAQ)

What is the Westhomes JR36 Motor Protection Relay? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The Westhomes JR36 Motor Protection Relay is a thermal overload protection device designed to protect AC motors from overload, phase failure, and abnormal operating conditions. It is commonly used with contactors to provide reliable motor protection in industrial control systems.

What is the main function of the JR36 Motor Protection Relay? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The main function of the JR36 Motor Protection Relay is to monitor motor current and disconnect the control circuit when overload conditions occur. It helps prevent motor overheating, insulation damage, and premature equipment failure.

What protection functions does the JR36 provide? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The JR36 provides thermal overload protection and phase failure protection. It detects excessive current caused by motor overload and helps protect motors from damage caused by abnormal operating conditions.

What applications are suitable for the JR36 Motor Protection Relay? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The JR36 is suitable for industrial motor applications such as pumps, fans, compressors, conveyors, machine tools, and automation equipment. It is widely used in motor control cabinets and low-voltage electrical systems.

What is the difference between a motor protection relay and an MPCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A motor protection relay mainly provides overload and phase failure protection and is usually installed together with a contactor. An MPCB combines motor switching, overload protection, and short-circuit protection in a single device.

Can the JR36 Motor Protection Relay protect against short circuits? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

No. The JR36 is designed for overload and phase failure protection. Short-circuit protection should be provided by additional protective devices such as fuses, MCBs, or MCCBs according to the electrical system requirements.

How does the JR36 protect a motor from overload? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The JR36 monitors the motor current through thermal elements. When the current exceeds the preset value for a certain period, the relay trips and disconnects the control circuit to prevent overheating and motor damage.

Can the JR36 be used with an AC contactor? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes. The JR36 Motor Protection Relay is designed to work together with AC contactors to create a complete motor starter solution. This combination provides motor control and overload protection for industrial applications.

How do I select the correct JR36 Motor Protection Relay? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The correct JR36 model should be selected according to the motor’s rated current, operating voltage, power rating, and application requirements. The overload setting should be adjusted according to the motor nameplate current to ensure effective protection.

Why choose the Westhomes JR36 Motor Protection Relay? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The Westhomes JR36 offers reliable overload protection, stable performance, and easy integration with motor control systems. It provides an effective solution for protecting industrial motors, improving operational safety, and extending equipment service life.