WRO1-63 1P+N Residual Current Breaker with Overvoltage Protection

All-in-one protection device with overvoltage protection. 6kA breaking capacity, selectable leakage sensitivity. Space-saving DIN rail design.

Social focus:

WRO1-63 1P+N Residual Current Breaker with Overvoltage Protection | 6kA Breaking Capacity

All-in-one protection device with overvoltage protection. 6kA breaking capacity, selectable leakage sensitivity. Space-saving DIN rail design.

The WRO1-63 1P+N is an advanced Residual Current Circuit Breaker with Integral Overcurrent Protection (RCBO) that also features integrated overvoltage protection, making it a comprehensive safety solution for single-phase applications.

Key Features:

4-in-1 Comprehensive Protection: Integrates overload protection, short-circuit protection, earth leakage protection, and overvoltage protection in a single compact module, saving valuable panel space.

Adjustable Residual Current Sensitivity: Available in three sensitivity options (30mA for personnel protection, 100mA for combined protection, 300mA for fire prevention) to match specific application requirements.

Integrated Overvoltage Protection: Safeguards connected equipment against dangerous voltage surges and fluctuations, preventing damage to sensitive electronics and appliances.

Compact 1P+N Design: Space-saving single-module width design, ideal for use in standard distribution boards where space is limited.

Applications:

Residential Electrical Panels

Home Office & Sensitive Electronics

Telecommunications Equipment

Renewable Energy Systems

WRO1-63 visual window
WRO1-63 original manufacturer
WRO1-63 test button
WRO1-63 din rail mount

Main Technical Parameters

Standard IEC/EN61009-1
Protection Ground fault, Overcurrent and short circuit
Type of trip Ground fault:Electronic/Magnetic
Overload and short circuit:Thermo-magnetic
No.of poles 1P+N,1 Module,Nline with disconnected
Type AC,A
Rated current In 6,10,16,20,25,32,40A
Rated sensitivity currents I△n 10,30,100,300mA
Residual current off-time under l△n ≤0.1s
Reted residual making and breaking capacity (I△m) 500A(In≤50A)
Rated voltage Ue 240V~
Rated frequency 50/60Hz
Rated breaking capacity 6KA
Energy limiting class 3
Rated impulse withstand voltage(1.2/50)Uimp 4,000V
Dielectric test voltage at ind.Freq.for 1min 2kV
Thermal release characteristic (1.13-1.45)x In
Magnetic release characteristic B:(3-5)x In,C:(5-10)x In
Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Yes
Protection degree IP20
Ambient temperature -25℃~+40℃,Max.95%humidity
Terminal connection type Cable/Pin-type busbar
Max.terminal size for cable 16mm2
Max.tightening torque 2.5N.m
Installation Mounting on 35mm DIN rail
Connection From top and bottom

Packaging and delivery

Selling Units Single item

Lead time

Quantity (pieces) 1 – 1,000 > 1,000
Lead time (days) 15 To be negotiated

Key attributes

Type MCB, AC MCB, RCBO
BCD Curve B, C
Rated Frequency (Hz) 50hz/60hz
Material Copper
Application Circuit-Breaking, Industrial, Households, Protection, Electric Power
Model Number WRO1-63
Rated Voltage 220V/230V
Breaking Capacity 6 kA
Mounting Type Rail Mounting
Protection LSI
Place of Origin Zhejiang, China
Brand Name Westhomes

FREQUENTLY ASKED QUESTION (FAQ)

What is the Westhomes WRO1-63 1P+N Residual Current Breaker with Overvoltage Protection? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The Westhomes WRO1-63 1P+N Residual Current Breaker with Overvoltage Protection is a multifunctional protection device that combines residual current protection, overvoltage protection, and circuit isolation functions. It is designed for single-phase electrical systems to improve safety and protect electrical equipment from leakage faults and abnormal voltage conditions.

What protection functions does the WRO1-63 provide? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WRO1-63 provides residual current protection to reduce electric shock risks, overvoltage protection to prevent damage caused by excessive voltage, and circuit disconnection protection during abnormal electrical conditions. It offers a comprehensive protection solution for low-voltage distribution systems.

What does 1P+N mean in the WRO1-63 residual current breaker? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

1P+N means the device contains one protected phase pole and one neutral pole. This configuration is designed for single-phase circuits, allowing simultaneous control and isolation of the phase and neutral conductors.

Where is the WRO1-63 1P+N residual current breaker commonly used? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WRO1-63 is widely used in residential buildings, commercial facilities, distribution boxes, lighting circuits, socket circuits, and other single-phase electrical applications where leakage and overvoltage protection are required.

What is the difference between WRO1-63 and a standard RCCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A standard RCCB mainly provides residual current protection against earth leakage faults. The WRO1-63 integrates additional overvoltage protection, allowing it to protect electrical systems from both leakage currents and abnormal voltage increases.

What is the rated current range of the WRO1-63? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WRO1-63 series supports different rated current options, allowing users to select a suitable model according to the load requirements and electrical system design.

How does the WRO1-63 protect against overvoltage? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

When the system voltage exceeds the preset safety limit, the WRO1-63 can quickly disconnect the circuit to help prevent damage to connected electrical equipment caused by abnormal overvoltage conditions.

Can the WRO1-63 be installed in a distribution box? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes. The WRO1-63 is designed for DIN rail installation, making it suitable for distribution boxes, consumer units, and electrical control cabinets where space-saving and reliable protection are required.

How do I choose the right WRO1-63 residual current breaker? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

When selecting the WRO1-63, consider the rated current, residual current sensitivity, operating voltage, electrical load type, and installation requirements. The selected model should match the protection needs of the specific application.

Why choose Westhomes WRO1-63 1P+N Residual Current Breaker with Overvoltage Protection? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The Westhomes WRO1-63 combines residual current protection and overvoltage protection in a compact 1P+N design. It provides reliable protection for single-phase electrical systems and is suitable for residential, commercial, and low-voltage distribution applications requiring enhanced electrical safety.

RELATED PROJECTS

REQUEST
YOUR FREE QUOTE

* indicates a required field