Manufacturer AC 50Hz/60Hz Wsb5-40 Low Voltage MCB Circuit Breaker

WSB5-40/WSB5 (L) -40 series MCB is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Social focus:

 WSB5-40/WSB5 (L) -40 Moulded case circuit breaker

WSB5-40/WSB5 (L) -40 is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Westhomes ACB and MCCB circuit breaker product series overview

WSB5-40 series “phae line + neutral line” circuit breaker is applied in single residential line of AC 50Hz or 60Hz, rated voltage 230V to make overload and short circuit protection to the electrical line. The product is big in breaking capacity and small in volume with width 18mm. It is null line and live line breakd at same time which put personal harm and risk an end that may caused by reverse connecting of null line or potential of null line earthing. It is the optimal distribution protecting switch for resisdual houses at present, meets standards IEC 60898 and GB 10963.1

WSB5L-40 sereis (phase + neutral + earth leakage) circuit breaker is applied in single phase residential line of AC 50Hz or 60Hz, rated voltage 230V for earth leakage protection, as well as protection of overload and short circuit for civil electrical line. The product is small in volume, big in breaking capacity. It can still make earth leakage protection even null and live lines cut meanwhile, and live line connects reversely. It meets standards IEC 61009 and GB 16917.1

KEY INFORMATION

WSB5-40/WSB5L-40

Pole 2P
Voltage AC230V
kA 4.5kA
Amps 6, 10, 16, 20, 25, 32,40
Width 18mm

Main technical parameters

Model Rated voltage (V) Pole (P) Frame current rating (A) Current rating (A) Rated short circuit breaking capacity Mechanical life (times)
Expected current test line (A) Power factor (cosΦ)
WSB5-40 230V 1P+N 40 6, 10, 16, 20, 25, 32, 40 4500 0.85~0.09 20000
  1. Anti-wetting type: class 2, humidity 95% when temperature 55ºC
  2. It uses connection terminal with clamp and hard wire below 10 mm2 for wiring
Model  Current rating (A) Rated voltage (V) Breaking capacity Earthing leakage action current Tripping feature Wiring  Width 
WSB5L-40 6, 10, 16, 20, 25, 32, 40 230V, 50Hz 4500A 30mA, class AC Type C 5-10In tripping instantaneous Wires 10mm2 and below 18mm
  1. Phase line + neutral line + earth leakage
  2. The product meets standard IEC 61009 and GB 16917.1

Product Range

Miniature Circuit Breaker (MCB) Upto 125A, 10kA, Curve type: A, B, C, D, 1P, 2P, 3P, 4P
Miniature Earth Leakage Circuit Breaker (MCB) (RCBO) Upto 125A, 10kA, 0.3mA, Curve type: A, B, C, D, 1P, 2P, 3P, 4P
Moulded Case Circuit Breaker (MCCB) Upto 2000A (adjustable), 100kA, 1P, 2P, 3P, 4P
Moulded Case Earth Leakage Circuit Breaker (ELCB) (RCCB) Upto 2000A (adjustable), 100kA, 1000mA, 1P, 2P, 3P, 4P
Universal Circuit Breaker (ACB) Upto 6300A, 100kA,
Switch Disconnector Upto 125A, 1P, 2P, 3P, 4P
Surge Arrestor Up 2.2/2.8kV, 100kA
Double Power Supplies Automatic Changeover Switch Upto 2000A, 7.5kA, 1P, 2P, 3P, 4P
Load Switch Disconnector Upto 3200A, 10kA, 70kA,
Distribution Box / Enclosure Plastic / Metal
Spare Parts

OVERALL AND MOUNTING DIMENSION(MM)

Wsb5-L-40

FREQUENTLY ASKED QUESTION (FAQ)

What is the WSB5-40 series, and where does it sit in Westhomes' MCB range? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB5-40 is Westhomes' compact low-voltage miniature circuit breaker (MCB) family built around a 40 A frame size, designed for residential and light-commercial final distribution. It is the smaller, household-oriented counterpart to higher-current WSB1-125 type breakers. The series covers the everyday protection tasks — lighting, sockets, fan and small appliance circuits — where a 40 A frame is more than enough.

What exactly does "low voltage" mean for this WSB5-40 MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

In this context "low voltage" refers to the IEC definition of nominal voltages up to 1000 V AC, and in practice the WSB5-40 is rated for 230 V AC single-phase (up to about 400 V AC in three-phase variants). It is therefore intended for building final distribution, the domestic switchboard and similar low-voltage networks — not for upstream or medium-voltage work. It must never be used above its rated operational voltage Ue.

Why is the 50 Hz / 60 Hz rating important, and can I use one breaker in both markets? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The rated frequency tells you the supply AC waveform the breaker is calibrated for. Because the thermal release responds to RMS current and the magnetic release responds to peak current, both 50 Hz and 60 Hz supplies fall well inside the design window of a low-voltage MCB, so the same WSB5-40 can ship to 50 Hz Europe/Asia and 60 Hz Americas without re-engineering. It is not intended for DC systems or for frequencies outside the 50/60 Hz band.

How is the WSB5-40 different from a fuse or a switch? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Unlike a fuse, which must be physically replaced after it blows, an MCB like the WSB5-40 trips mechanically and is simply reset with the toggle once the fault is cleared. Unlike a plain switch, it automatically disconnects on overload and short-circuit, and it combines both functions in one DIN-rail enclosure. It also provides a visibly open contact position for isolation during maintenance.

What breaking capacity can I expect from the WSB5-40 in a typical home? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB5-40 is typically rated for a 6 kA short-circuit breaking capacity at 230 V AC, which is the standard figure for household MCBs and is adequate for the vast majority of domestic consumer units. That means it can safely interrupt up to 6 000 A of prospective fault current without being destroyed. If the board is very close to a large transformer, an engineering calculation should confirm the actual prospective short-circuit current at the board.

Can the WSB5-40 be used as the main switch of a small distribution board? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

As a 40 A frame MCB it is generally used as a branch or final-circuit breaker rather than as the incomer. For a small domestic installation whose total load stays below 40 A it can double as a protective main switch, but for larger homes and commercial boards the main switch should be a higher-rated device such as a WSB1-125 or an MCCB. Always size the incomer breaker above the sum of the downstream breakers' trip settings with discrimination in mind.

What certifications does this WSB5-40 low-voltage MCB carry? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB5-40 is tested and certified to IEC 60898-1 (over-current protective MCBs for household and similar installations) and bears CE marking, indicating conformity with the applicable European Low Voltage Directive and EMC requirements. Many export variants are also tested to equivalent national standards such as GB 10963.1 in China. When ordering for a specific country, confirm the required certification on the certificate of conformity.

Is the WSB5-40 suitable for sensitive electronic loads such as LED lighting or chargers? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes, provided you pick the correct trip curve. A B-curve WSB5-40 is the natural choice for LED drivers, electronic ballasts and IT loads, because its lower instantaneous trip threshold gives faster protection against small short-circuits without being upset by capacitive inrush. Avoid a D-curve on purely electronic loads, as its 10–20 × In magnetic threshold can delay fault disconnection.

Does the WSB5-40 provide earth-leakage (RCD/RCBO) protection by itself? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

No. The WSB5-40 is a pure MCB: it protects only against overload and short-circuit. It does not detect earth leakage (residual current) and will not trip on a person touching a live part. For shock protection and fire protection against earth faults, pair it with a separate RCCB upstream or select an RCBO variant that combines MCB and residual-current protection in one unit.

How should the WSB5-40 be stored, installed and serviced over its life? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Store it in its original packaging in a dry, dust-free location within the manufacturer's stated temperature range (typically −25 °C to +60 °C). Install it on a 35 mm DIN rail inside an enclosure with the correct IP rating for the location, torque the terminals to the value on the nameplate, and never exceed the number of conductors or the wire size listed. Because it is a sealed, non-user-serviceable device, the only routine maintenance is an annual visual check and a manual trip/reset exercise to confirm the mechanism still moves freely.