Manual Type High Speed Circuit Breaker Wcm9z 100A-630A ODM OEM

WCM9Z series MCB is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Social focus:

WCM9Z Moulded case circuit breaker

WCM9Z is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Westhomes ACB and MCCB circuit breaker product series overview

WCM6 sereis moulded case circuit breaker (MCCB for short) is the new type of product with top current limiting principal and manufacture technology in design, is tight in structure, total molularized, high breaking capacity, zero flashover. It applies at AC50Hz, rated operation voltage 690V and below, rated operation current upto 1250A for infrequent switch of line and infrequent start of motor. MCCB has overload, short circuit and under voltage protection device, to protect line and power evice from demage.

KEY INFORMATION

WCM9Z

Pole  2P, 3P
Voltage  DC 1000V/1250V/1500V
kA  Ue1000v 20kA, Ue1500v 15kA
Inm(A)  250A, 630A
In(A)  100/125/140/160/180/200/225/250/320/350/400/500/630A

MAIN TECHNICAL DATA

Model WCM9Z WCM9Z WCM9Z
Rated operating voltage(Ue) DC1000V DC1250V DC1500V DC1000V DC1250V DC1500V
Rated insulation voltage (Ui) 1500V 1500V 1500V
Rated impulse voltage (Uimp) 12kV 12kV 12kV
Number of poles 2 3 4
Trip unit type Thermomagnetic type (thermal magnet is not adjustable) TMD Fixed
Frame rated current (Inm) 250A 630A
Rated operating current (In) 100/125/140/160/180/200/225/250A 320/350/400/500/630A
Rated ultimate short circuit breaking capacity (lcu) Ue1000v 20kA Ue1500v 15kA, Ue1250v 20kA Ue1250/1500v 15kA, Ue1000v 20kA
Operational breaking capacity (Ics) 75%ICU Ue1500v 15kA, Ue1250v 20kA Ue1250/1500v 15kA, Ue1000v 20kA
Protective function Long time delay protection (Ir) 1In
Instant protection (li) 6In(Min1000A)
Service life Mechanical 10000times 5000times
Electrical 1000times 500times
Installation type Fixed Fixed Fixed
Protection level Wiring port: IP20/All sides: IP40
Operating temperature -40ºC~+75ºC
Operating Instructions ON/OFF instruction
Is the release adjustable? NO
Isolation function YES

FREQUENTLY ASKED QUESTION (FAQ)

What is a high-speed circuit breaker? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A high-speed circuit breaker is a specialized protection device designed to open and interrupt a short-circuit fault in a fraction of the time of a conventional MCCB or ACB — typically within a few milliseconds to a half-cycle (8–10 ms at 50/60 Hz). It achieves this through an optimized fast operating mechanism (often spring-loaded or electromagnetic repulsion drive) and specialized arc extinguishing. Its purpose is to limit the fault current before it reaches its peak, thereby dramatically reducing mechanical and thermal stress on cables, busbars, and connected equipment.

How does the WCM9Z achieve such fast tripping? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM9Z uses a high-performance, spring-loaded, quick-break mechanism with a toggle linkage designed for minimal overtravel and direct contact separation on trip. When the trip unit detects a fault, the stored spring energy drives the contacts apart almost instantly, and the arc is rapidly swept into a dedicated arc chute. Total clearing time is far below that of a standard molded-case breaker, limiting the peak let-through current and I²t energy delivered to the system.

What does the 100A–630A current range cover? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM9Z is available in frame current ratings from 100A up to 630A, meaning it can protect circuits carrying continuous currents in that range. This covers medium-sized motor feeds, main feeder circuits, capacitor bank switching, and DC distribution panels. Within each frame size, rated current (In) can be adjusted via plug-in or interchangeable trip units to match the actual load, allowing one frame size to cover multiple current ratings.

What does "manual type" mean? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

"Manual type" means the breaker is operated locally by a manual toggle or push-button handle — it does not include a motor charging mechanism or electric closing release as standard. Closing and opening are performed by a person at the panel. Tripping itself remains automatic under fault conditions (thermal or magnetic release); the "manual" description refers to normal on/off operation, not fault tripping. Shunt releases or undervoltage releases can be added for remote trip if required.

How does the WCM9Z compare to a standard MCCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A standard MCCB typically clears a short circuit in 1.5–2 cycles (30–40 ms at 50/60 Hz), while a high-speed breaker like the WCM9Z clears in under one quarter to one half cycle (5–10 ms). This means the WCM9Z limits the fault current to a small fraction of its prospective peak, drastically reducing stress on the installation. Standard MCCBs are cheaper and more widely available; the WCM9Z is chosen specifically for applications where equipment protection, voltage-dip reduction, or fault-energy limitation is paramount.

What are the main applications of the WCM9Z? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM9Z is commonly used in: capacitor bank switching (where fast interruption prevents restrike and inrush damage), DC systems including battery banks and DC distribution in substations, welding equipment and rectifier circuits, semiconductor fab and DC plant supplies, traction power, and any installation where very fast fault clearing protects expensive equipment or limits fire/arc-flash risk. It is also used in places requiring current-limiting performance to lower system short-circuit duties.

What is its breaking capacity? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

As a high-speed breaker, the WCM9Z is designed with a high breaking capacity suitable for the 100A–630A frame range, optimized for current-limiting performance. Because it trips so quickly, the actual peak fault current it sees is far lower than the prospective rms fault current — this is the essence of current-limiting design. Refer to the datasheet for the exact Icu (ultimate breaking capacity) at the rated voltage for the specific frame size and trip unit configuration.

How is the WCM9Z installed? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM9Z is typically panel-mounted via bolted terminals or busbar connections, matching conventional MCCB installation practices. Line and load conductors are connected to the labeled terminals at the correct torque. Because it is a current-limiting high-speed device, ensure downstream busbars and cables are sized for the magnetic forces of the prospective fault current even though the breaker limits duration. Refer to the installation manual for clearances, creepage distances, and terminal lug options.

Does the WCM9Z comply with IEC 60947-2? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes, the WCM9Z is designed and type-tested to IEC 60947-2, which covers low-voltage AC and DC circuit-breakers up to 1000V AC and 1500V DC. Its fast operating characteristics and high current-limiting performance are achieved within the framework of this standard, including verified breaking capacity, short-time withstand, endurance, and marking requirements. Compliance allows it to be specified for international industrial and infrastructure projects.

What maintenance does the WCM9Z require? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM9Z requires minimal maintenance due to its simple manual mechanism. Periodically (every 1–2 years under normal conditions), inspect terminal tightness, check that the handle operates smoothly, and wipe dust or contamination from the housing. After a major fault interruption, inspect the contacts and arc chute (if accessible) or consider replacing the breaker depending on fault magnitude and manufacturer guidance. Electronic trip units (if fitted) should be current-injection tested every 3–5 years to confirm calibration.