The WSB1Z-63 is a 6kA double-pole DC miniature circuit breaker for solar photovoltaic systems. Rated up to 63A and 500V DC, it provides overcurrent and short-circuit protection on the DC side of PV installations, suitable for solar combiner boxes, inverters, and DC distribution panels.

Social focus:

WSB1Z-63 6kA 2P DC Miniature Circuit Breaker for Solar PV Systems

The WSB1Z-63 is a 6kA double-pole DC MCB rated up to 63A and 500V DC. It handles overcurrent and short-circuit protection on the DC side of photovoltaic systems, commonly installed in solar combiner boxes, inverter inputs, and DC distribution panels.

Westhomes ACB and MCCB circuit breaker product series overview

The WSB1Z-63 is a 6kA double-pole DC miniature circuit breaker rated up to 63A. It operates in DC circuit systems at four standard voltage levels: 250V, 500V, 750V, and 1000V DC, covering most residential and commercial PV installations.

The breaker protects against overload and short-circuit conditions on the DC side of photovoltaic systems. A double-pole design isolates both positive and negative conductors simultaneously, which is required by most solar installation codes for DC circuit protection. It also supports infrequent manual switching for maintenance and circuit isolation.

Typical applications include solar combiner boxes, inverter DC inputs, battery charge controllers, and DC distribution panels. The product is widely used in rooftop PV systems, solar farm sub-arrays, and off-grid power setups in commercial and residential buildings.

Complies with GB 10963.2 and IEC 60898-2. Available in 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, and 63A ratings. DIN rail mounting, standard 35mm profile.

KEY INFORMATION

WSB1Z-63

Frequency  50Hz/60Hz
          Pole  1, 2, 3, 4P
          Voltage  DC250V/500V/750V/1000V
          kA  6kA
          Amps  6-63A
          Width  18, 36, 54, 72mm
          Mounting  Din rail

MAIN TECHNICAL DATA

Model Ics/Icn) pole rated current(A)
WSB1Z-63 (6kA/6kA) 1P 6A-63A
WSB1Z-63(6kA/6kA) 2P 6A-63A
WSB1Z-63 (6kA/6kA) 3P 6A-63A
WSB1Z-63(6kA/6kA) 4P 6A-63A

FREQUENTLY ASKED QUESTION (FAQ)

What is the Westhomes 6 kA Double Pole DC isolator MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is a 2-pole DC miniature circuit breaker with a 6 kA short-circuit breaking capacity, used as a DC-side isolator and overcurrent protector between solar panels and the inverter. Because both poles open together, it physically disconnects both the positive and negative DC conductors from the array.

What does "6 kA breaking capacity" mean? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It means the breaker can safely clear a short-circuit current of up to 6,000 A at its rated voltage without damage. A 6 kA rating is typical for residential and small commercial PV systems where the maximum available fault current from the string and inverter is well below that level.

Why is double pole (2P) important for a solar isolator? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 2-pole breaker opens both the positive (+) and negative (-) lines simultaneously. A single-pole isolator would leave one conductor energized even when "off," creating a shock hazard and a path to ground through the array. 2P isolation is the safer and code-preferred arrangement for PV DC sides.

How is it different from a pure DC isolator switch? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A pure isolator switch only opens the circuit manually for maintenance and does not provide automatic overcurrent or short-circuit protection. This 6 kA double-pole MCB combines isolation with a thermal-magnetic trip that automatically opens on overload or fault, so it both isolates and protects.

What DC voltage is this isolator rated for? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is rated for DC photovoltaic system voltages, commonly up to 1000 V DC, matching typical residential and small-commercial solar arrays. Confirm the exact Ue (rated operational voltage) on the label and ensure it exceeds the cold-weather Voc of your string.

How do I wire it to my solar panels? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Mount the 2P breaker on a DIN rail in a combiner or DC distribution box. Run the PV positive and negative from the panel strings to the line (source) terminals, observing the +/- polarity, and run the corresponding conductors to the inverter on the load side. Tighten lugs to the manufacturer's torque.

Can I use this isolator to turn off the inverter for servicing? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes — opening the double-pole handle isolates the entire DC input to the inverter, which is the standard way to shut down the PV array for maintenance. Always verify with a voltage tester that the inverter DC input is dead before working, since the panels remain live in daylight.

Does it meet PV safety standards? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is designed to IEC 60947-2 for low-voltage circuit breakers and used in installations following IEC 60364-7-712 (PV systems). The 6 kA rating and 2P opening are the key characteristics expected of a DC solar isolator certified for photovoltaic service.

Why might it trip even though I just want to isolate? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

If the breaker trips automatically rather than staying open under manual operation, it is detecting an overload or short circuit on the DC side — for example a ground fault, pinched cable, or defective inverter input. Investigate the fault first; a breaker that opens on its own is doing its protective job, not simply acting as an isolator.

What current ratings are available for this 6 kA 2P isolator? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

This style of 2P DC isolator MCB is offered in standard current ratings such as 16 A, 32 A, 40 A, 63 A, and 80 A. Choose the rating so that In is at least 1.25 × the string Isc and above the normal operating current, while keeping the 6 kA breaking capacity matched to the system's fault level.