WNB1-63 MCB 6kA Miniature Circuit Breaker | B/C/D Curve
Westhomes WNB1-63 1P Miniature Circuit Breaker – Reliable Overload & Short Circuit Protection for Single-Phase Circuits.
Get quick appointment for technical support!
Shop the Westhomes WNB1-63 1P MCB. 230V single-pole protection with 6kA breaking capacity. Available in B/C/D curves. DIN rail mount. Ideal for home lighting.
Westhomes WNB1-63 1P Miniature Circuit Breaker – Reliable Overload & Short Circuit Protection for Single-Phase Circuits.

The Westhomes WNB1-63 Series 1P MCB is designed to protect single-phase lighting and socket circuits against overloads and short circuits. Engineered for residential and commercial distribution boards, this single-module (18mm) breaker maximizes space efficiency while delivering high-performance protection.
Key Features:
Single Pole Protection: Switches and protects the phase (live) conductor only, ideal for final sub-circuits.
High Breaking Capacity: Features a 6kA rated short-circuit capacity, ensuring rapid fault clearance to safeguard downstream equipment.
Multiple Tripping Curves: Available in B, C, and D curves. The C-curve characteristic is perfectly suited for standard lighting and receptacle loads.
Wide Application: Rated for 230V AC at 50/60Hz, compatible with global residential power standards.
Easy Installation: Complies with standard 35mm DIN rail mounting for quick and secure snap-on installation with lift terminals for firm wiring.
Applications
Residential lighting circuits, general-purpose socket outlets, small appliances, and control transformers.




| Type | MCB |
| BCD Curve | B, C, D |
| Rated Frequency (Hz) | 50hz/60hz |
| Material | Copper |
| Application | Circuit-Breaking |
| Model Number | WNB1-63 Series |
| Rated Voltage | 220V/230V, 400 V |
| Breaking Capacity | 6 kA |
| Mounting Type | Rail Mounting |
| Protection | Li |
| Place of Origin | Zhejiang, China |
| Brand Name | Westhomes |
| Standard | IEC/EN 60898-1 |
| Protection | Overcurrent and short circuit |
| Type of trip | Thermo-magnetic |
| No.of poles | 1P,1P+N,2P,3P,3P+N,4P |
| Rated currents(In) | 1,2,3,4,5,6,8,10,16,20,25,32,40,50,63A |
| Rated voltage(Ue) | 240/415V~ |
| Rated frequency | 50/60Hz |
| Rated breaking capacity | 3KA,4.5KA,6KA. |
| Rated impulse withstandard voltage(1,5/50)Uimp | 4,000V |
| Dielectric test voltage at Ind.Freq.for 1 min | 2kV |
| Thermal release characteristic | (1.13-1.45)x In |
| Magnetic release characteristic | B:(3-5)x In,C:(5-10)x In,D:(10-20)x In |
| Electrical life | 4,000 Cycles |
| Mechanical life | 10,000 Cycles |
| Contact position indicator | Yes |
| Protection degree | IP20 |
| Ambient temperature | -5℃ to+40℃,Max.95%humidity |
| Terminal connection type | Cable/Pin-type busbar |
| Installation | Mounting on 35mm DIN rail |
| Connection | From top and bottom |
| Selling Units | Single item |
| Quantity (pieces) | 1 – 1,000 | > 1,000 |
| Lead time (days) | 15 | To be negotiated |
The Westhomes WNB1-63 is a thermomagnetic miniature circuit breaker designed to protect low-voltage electrical circuits against overload and short circuits. The series is available in different pole configurations and rated current options, making it suitable for residential, commercial, and light industrial applications.
The WNB1-63 series is available with rated short-circuit breaking capacities of 3kA, 4.5kA, and 6kA. For the 6kA version, the breaker can interrupt a prospective short-circuit current up to its specified 6kA rating under the applicable test conditions. The selected breaking capacity should be higher than the prospective short-circuit current at the installation point.
The WNB1-63 series covers rated currents from 1A to 63A, including 1A, 2A, 3A, 4A, 5A, 6A, 8A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, and 63A. The appropriate rating should be selected according to the actual load current and the current-carrying capacity of the protected cable.
The WNB1-63 series is rated for 240/415V AC and operates at 50/60Hz. Depending on the pole configuration, it can be used in suitable single-phase or three-phase low-voltage distribution systems.
The WNB1-63 series is available with B, C, and D magnetic tripping characteristics:
B Curve: 3–5 × In
C Curve: 5–10 × In
D Curve: 10–20 × In
B-curve MCBs are generally used for low-inrush loads, C-curve MCBs are suitable for general electrical loads, while D-curve MCBs are intended for applications with higher starting or inrush currents.
Yes. The WNB1-63 series is available in 1P, 1P+N, 2P, 3P, 3P+N, and 4P configurations. This allows the series to cover a wide range of single-phase and three-phase low-voltage applications. The correct pole configuration should be selected according to the electrical system and whether the neutral conductor needs to be switched.
The main difference is their instantaneous magnetic tripping range. B-curve breakers trip at a lower multiple of rated current and are suitable for loads with little inrush current. C-curve breakers provide a balance between sensitivity and tolerance to starting current and are widely used for general loads. D-curve breakers tolerate significantly higher inrush currents and are more suitable for inductive loads such as motors and transformers.
WNB1-63 MCBs can be used in residential distribution boards, commercial buildings, lighting circuits, socket circuits, small electrical equipment, control circuits, and light industrial applications. The 6kA version is suitable where the required short-circuit breaking capacity is within its specified rating.
The WNB1-63 is designed for installation on a standard 35mm DIN rail, making it suitable for modular distribution boards and switchgear. It supports cable and pin-type busbar connections, with terminals that allow connection from the top or bottom.
Selecting the correct WNB1-63 MCB requires consideration of several factors:
Rated current: Match the MCB rating with the load current and cable capacity.
Voltage: Confirm that the breaker is suitable for the system voltage.
Breaking capacity: Select a breaking capacity that exceeds the prospective short-circuit current.
Tripping curve: Choose B, C, or D according to the characteristics of the load.
Pole configuration: Select 1P, 1P+N, 2P, 3P, 3P+N, or 4P according to the circuit configuration.
Installation: Confirm compatibility with the distribution board and 35mm DIN rail.
Westhomes can provide technical support to help customers select the appropriate WNB1-63 configuration according to their application requirements.
* indicates a required field