3 Pole 400A MCCB – WCM8E-250M

The WCM8E-250M 3 Pole 400A Molded Case Circuit Breaker (MCCB) is a high-performance, CE and CB certified circuit protection device engineered for demanding low-voltage applications.

Social focus:

3 Pole 400A MCCB | WCM8E-250M CE/CB Certified Molded Case Circuit Breaker

The WCM8E-250M is engineered to deliver consistent performance across various sectors, including manufacturing, construction, marine, and energy.

WCM8E-125M

Designed using advanced international technologies, this MCCB offers exceptional electrical protection and high breaking capacity, making it ideal for large-scale distribution systems, industrial machinery, and marine electrical networks.

With a rated insulation voltage of 800V and rated operating voltage up to 690V, this 3-pole MCCB is built to handle heavy loads and ensure operational safety. It supports infrequent line switching and motor starting under AC 50Hz frequency, making it suitable for mission-critical applications where electrical stability is essential.

This model supports 400A rated current, offering robust protection against overload, short circuits, and under-voltage conditions. The MCCB is compact in size yet powerful in performance, providing a reliable circuit-breaking solution that minimizes risk and maximizes uptime.

KEY INFORMATION

Model Frame level rated current (A) Current Rating (A) Rated operation voltage (V) Rated insulation voltage (V) Rated ultimate short circuit breaking capacity (kA) 400V Rated operation short circuit breaking capacity (kA) 400V
WCM8-63L 63 (6), 10, 16, 20, 25, 32, 40, 50, 63 AC400 AC500 25 18
WCM8-63M 50 35
WCM8-125C 100 (10), 16, 20, 25, 32, 40, 50, 63, 80, 100 AC690 AC800 20 10
WCM8-125L 35 17.5
WCM8-125M 50 35
WCM8-125H 85 50
WCM8-250L 225 100, 125, 140, 160, 180, 200, 225 AC690 AC800 35 18
WCM8-250M 50 35
WCM8-250H 85 50
WCM8-400L 400 225, 250, 315, 350, 400 AC690 AC800 50 25
WCM8-400M 65 42
WCM8-400H 100 65
WCM8-630L 630 400, 500, 630 AC690 AC800 50 25
WCM8-630M 65 42
WCM8-630H 100 65
WCM8-800M 800 630, 700, 800 AC690 AC800 75 50
WCM1-800H 100 65
WCM8-1250 800 1000, 1250 AC690 AC800 65 40
WCM8-2000 1250 1400, 1600, 1800, 2000 AC690 AC800 65 40
Description Specification
Frame level rated current Inm(A) 63 125 250 400 630 800 1250
Breaking the capacity level L M C L M H L M H L M H L M H M H
Overall Dimensions
(mm)
Overall Dimensions
W 75/103 65/93/107 74.5/107/142 150/198;定140/184 182/238 210/280 210/280
L 136 150 165 257;定257 270 280 466
H 66.5 61 79 81 99 102;定108 105.5 107.5 139
H1 90.5 86 104 110 127 151.5;定146 155 155 190
Mounting Dimensions
(mm)
Mounting Dimensions
A 25 30 35 44/90;定44/88 58 70 70
B 115 130.5 126 194;定215 200 243 300
Φd 3.5 4.5 5 7;定6.5 7 7 9.5

Basic Info.

Model NO. WCM8E-250M
Arc-extinguishing Medium Air
Structure MCCB
Type Circuit Breaker
Certification ISO9001-2000, CE, CB, CCC
Factory Own
Payment L/C, T/T, D/P, Western Union, Paypal, Money Gram
Specification 10A-800A
Origin China
Production Capacity 5000PCS/Week
Speed High-Speed Circuit Breaker
Installation Fixed
Poles Number 3p, 4p
Function Conventional Circuit Breaker,
Circuit-Breaker Failure Protection,
Overcurrent Protection,
OVP(Overvoltage Protection)
Production Line 100% Automic
Cooperation Type OEM ODM
Transport Package Paper Box
Trademark Westhomes
HS Code 8536200000

FREQUENTLY ASKED QUESTION (FAQ)

What is an MCCB and how does it work? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A Molded Case Circuit Breaker (MCCB) is an over-current protective device that interrupts a circuit automatically on overload or short circuit. It combines a thermal element that bends a bimetal strip over time on sustained overload and an electromagnetic solenoid that trips instantly on very high fault current. The WCM8E-250M packages both mechanisms inside a rigid insulating molded case with a manual operating handle.

What does the "400A, 3 Pole" rating mean for the WCM8E-250M? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The 400A is the maximum continuous current the breaker can carry without tripping, and 3 Pole means it switches and protects all three phases of a three-phase system. It is typically used as a main or feeder breaker in 400V-class three-phase distribution. Because it opens all three poles together, it prevents a single-phase condition from being left energized after a fault.

What is adjustable thermal-magnetic tripping and why is it useful? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Thermal-magnetic tripping means the breaker has a thermal (time-delay) trip for overloads and a magnetic (instantaneous) trip for short circuits. On the WCM8E-250M you can usually set the rated current (Ir) and, in electronic versions, the instantaneous threshold (Ii) to match the actual cable and load. This lets you coordinate downstream devices and avoid nuisance trips without sacrificing short-circuit protection.

What is breaking capacity and why does it matter? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Breaking capacity (rated ultimate short-circuit breaking capacity, Icu) is the maximum fault current the breaker can safely clear without destruction. A 35kA or 50kA-rated MCCB is required where the upstream transformer can deliver a high prospective short-circuit current. Selecting a breaker with Icu below the available fault level risks violent failure, so the installed value must always exceed the calculated prospective short-circuit current at the point of installation.

How is an MCCB installed in switchgear? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM8E-250M is generally mounted on a chassis or DIN/stud fixing inside a distribution board or cabinet, with busbars or cables connected to line (supply) and load terminals. It should be installed upright, with adequate clearance around operating and terminal areas, and isolated by a properly rated isolator for maintenance. Accessories such as shunt releases, undervoltage releases, auxiliary contacts, and motor operators can be fitted to extend control and monitoring.

What wiring considerations apply when installing this 400A breaker? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Use copper lugs sized to the 400A rating (typically 185–240 mm² depending on cable length and derating), torque all terminals to the manufacturer's value, and keep conductors straight near the terminals. Match line and load orientation (marked "1/2/3" on line, "2/4/6" on load) unless the device is stated reversible. Ensure earth and neutral are routed separately so no current-carrying conductor passes through the breaker's current sensing in a way that affects its protection.

Can the WCM8E-250M be used for motor protection? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes, but it must be selected with a suitable motor-protective (M) trip curve so that the locked-rotor starting current (typically 6–10× rated) does not cause instantaneous tripping during start-up. An MCCB used as a motor circuit protector provides short-circuit and earth-fault backup, while a separate overload relay (e.g., in a contactor+overload starter) handles running overload. The trip setting must be coordinated with the motor full-load current.

Which standard does this MCCB comply with? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM8E-250M is designed and type-tested to IEC 60947-2, which covers low-voltage switchgear and controlgear—specifically circuit-breakers for over-current protection. The standard defines rated voltages, currents, short-circuit breaking capacity (Icu/Ics), utilization categories (e.g., A or B), and trip characteristics. CE marking and related regional certifications confirm conformity to applicable safety and EMC requirements.

What routine maintenance does an MCCB require? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Periodically inspect the breaker for physical damage, check terminal tightness with a torque wrench, and operate the manual trip/test mechanism to confirm mechanical freedom. Keep the interior clean and dry, and record trip events; if the breaker has cleared a major short circuit, it should be inspected or replaced by a qualified electrician even if it appears to reset. Do not attempt to dismantle the molded case, as the arc chute and contacts are factory-sealed.

How is an MCCB different from an MCB and an ACB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

MCBs are small, DIN-rail, fixed-trip devices generally up to 125A with lower breaking capacity, used for final circuits. MCCBs like the WCM8E-250M cover roughly 16A–1600A with adjustable settings and high breaking capacity, used for feeders and mains. Air Circuit Breakers (ACBs) are larger, draw-out or fixed breakers from ~630A upward, used as main incomers with advanced protection and communication. In short: MCB for circuits, MCCB for feeders, ACB for the main switch.