WNB1-63 4P MCB 6kA Four Pole Circuit Breaker

Shop Westhomes WNB1-63 4P MCB with 6kA breaking capacity. Ideal for 415V systems, this Four Pole Circuit Breaker isolates Phase and Neutral.

Social focus:

WNB1-63 4P MCB 6kA Four Pole Circuit Breaker | 415V 3-Phase + Neutral

Westhomes WNB1-63 4P Miniature Circuit Breaker – Complete Isolation for Three-Phase Systems with Neutral.

The Westhomes WNB1-63 4P MCB is the ultimate solution for applications requiring total isolation and protection of all incoming conductors. By protecting all three phases and the neutral conductor, this breaker ensures absolute safety for maintenance personnel and equipment in complex three-phase installations.

Key Features:

Full System Isolation: Switches and protects all four poles (L1, L2, L3, N), ensuring no live parts remain when the breaker is in the “OFF” position.

Neutral Protection: Unlike switched neutrals, the 4P design provides overload and short circuit protection on the neutral in applicable configurations (depending on network type).

Reliable 6kA Performance: Maintains consistent breaking capacity across all poles for dependable fault clearing.

Adaptable Tripping: Available in B, C, and D curves, allowing customization for everything from electronic loads to high-induction machinery.

Universal Mounting: Standardized housing for DIN rail systems, making it easy to integrate into main distribution boards (MDBs).

Applications

Main switch for small workshops, three-phase distribution boards requiring neutral isolation, server rooms, and industrial control panels.

Key attributes

Type MCB
BCD Curve B, C, D
Rated Frequency (Hz) 50hz/60hz
Material Copper
Application Circuit-Breaking
Model Number WNB1-63 Series

Rated Voltage 220V/230V, 400 V
Breaking Capacity 6 kA
Mounting Type Rail Mounting
Protection Li
Place of Origin Zhejiang, China
Brand Name Westhomes

Standard IEC/EN 60898-1
Protection Overcurrent and short circuit
Type of trip Thermo-magnetic
No.of poles 1P,1P+N,2P,3P,3P+N,4P
Rated currents(In) 1,2,3,4,5,6,8,10,16,20,25,32,40,50,63A
Rated voltage(Ue) 240/415V~
Rated frequency 50/60Hz
Rated breaking capacity 3KA,4.5KA,6KA.
Rated impulse withstandard voltage(1,5/50)Uimp 4,000V
Dielectric test voltage at Ind.Freq.for 1 min 2kV
Thermal release characteristic (1.13-1.45)x In
Magnetic release characteristic B:(3-5)x In,C:(5-10)x In,D:(10-20)x In
Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Yes
Protection degree IP20
Ambient temperature -5℃ to+40℃,Max.95%humidity
Terminal connection type Cable/Pin-type busbar
Installation Mounting on 35mm DIN rail
Connection From top and bottom

Packaging and delivery

Selling Units Single item

Lead time

Quantity (pieces) 1 – 1,000 > 1,000
Lead time (days) 15 To be negotiated

FREQUENTLY ASKED QUESTION (FAQ)

What is a 4P MCB and when do I use it? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 4-pole MCB protects and switches all four conductors of a three-phase-and-neutral circuit — L1, L2, L3, and N — together on one handle. Use it where you want to protect and isolate a three-phase load that also needs the neutral switched, such as a three-phase distribution branch, a panel incomer, or equipment requiring all poles isolated on trip.

What does the 6 kA breaking capacity mean? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The 6 kA rating is the rated short-circuit breaking capacity: the maximum prospective fault current (6000 A) the breaker can safely interrupt and clear. Because three-phase panels near transformers can see high fault levels, the 6 kA rating makes this MCB suitable for modern commercial/industrial boards; it must still be ≥ the calculated available fault current at its location.

How does the WNB1-63 MCB trip? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It uses the same thermal-magnetic principle as other MCBs: a bimetallic strip heats and bends to give a delayed trip on sustained overload, while a solenoid plunger releases instantly on a short circuit. The four poles are mechanically linked so that a fault on any pole opens all of them together, and the arc is quenched in internal arc chutes.

What tripping curves are available (B/C/D)? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Like other MCBs, WNB1-63 units are typically offered in B, C, or D curves determining the instantaneous trip range. Type C is the most common for general three-phase and motor-circuit duty, B for low-inrush resistive loads, and D for high-inrush loads such as transformers or large motor starts — confirm the exact curves and ratings offered on the datasheet.

How does a 4P MCB differ from a 3P MCB plus a separate neutral? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 4P breaker switches and links the neutral with the three phases in one device, so all four poles open together. A 3P breaker protects only the phases, leaving the neutral on a separate terminal bar. Choose 4P when you require the neutral to be switched or isolated together with the phases, per local wiring rules.

How do I size the current rating for a three-phase load? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Calculate the full-load current of the three-phase load, size the conductors to carry it, and select an MCB rating (In) above the design current but not exceeding the cable's ampacity. Account for the load type in choosing the B/C/D curve so motor or transformer inrush does not cause nuisance trips.

How is a 4P MCB installed on DIN rail? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Clip the breaker onto a standard 35 mm DIN rail in the distribution board, then connect L1/L2/L3 and the neutral to the correspondingly marked line terminals and the load-side conductors to the load terminals. Observe the marked line/load orientation, tighten terminals to datasheet torque, and keep the supply isolated during wiring.

What is the rated voltage for a 4P three-phase MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 4-pole MCB of this type is normally rated for three-phase AC (commonly 400 V between phases, per IEC 60898-1). Confirm the exact rated voltage and the number of protected poles on the nameplate, because voltage and pole ratings must match the supply being protected.

What should I check if a 4P MCB trips repeatedly? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Look first for an overload (load current above the rating on one or more phases), a phase-to-phase or phase-to-neutral short circuit, or a failed connected three-phase appliance. Balance the phases, isolate loads one at a time, and inspect wiring and terminals for damage — repeated resetting without finding the cause is unsafe.

Which standard and mark does it meet? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WNB1-63 4P MCB is a low-voltage miniature circuit breaker covered by IEC 60898-1 and commonly marked CE for the EEA market. Always check the datasheet for the exact rated current, breaking capacity, and curve markings that define its actual duty.