Westhomes Wsb9-80 Miniature Air Low Voltage Circuit Breaker 2p with AC230V400V 50Hz/60Hz

WSB9-80 series MCB is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Social focus:

WSB9-80 Moulded case circuit breaker

WSB9-80 is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Westhomes ACB and MCCB circuit breaker product series overview

WSB9 series Miniature circuit breakers (hereinafter referred to as circuit breakers) are suitable for AC 50Hz or 60Hz, rated working voltage AC230V/400V, rated current up to 80A lines, for overload and short circuit protection of the lines, and can also be used for infrequent operation conversion of the lines. The circuit breaker is suitable for commercial office buildings, residential buildings and similar buildings. This product complies with GB10963.1 and IEC60898-1 standards.

KEY INFORMATION

WSB9-80

Frequency  50Hz/60Hz
Pole  1, 2, 3, 4
Voltage  AC230V/400V
kA  6kA, 10kA
Amps  6, 10, 16, 20, 25, 32, 40, 50, 63, 80
Width  18, 36, 54, 72mm
Mounting  Din rail

MAIN TECHNICAL DATA

Model Pole Rated voltage Rated current Breaking capacity Types of instantaneous Current range of instantaneous protection
WSB9-63 1P, 2P, 3P, 4P AC230/400V 6, 10, 16, 20, 25, 32, 40, 50, 63, 80A N: 6kA(6-63A)
H: 10kA(6-63A)
B 3In<I≤5In
C 5In<I≤10In
D 10In<I≤50In

OVERALL AND MOUNTING DIMENSION(MM)

Westhomes Wsb9-80 Miniature Air Low Voltage Circuit Breaker 2p with AC230V400V 50Hz/60Hz

FREQUENTLY ASKED QUESTION (FAQ)

What is the WSB9-80 2P used for? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB9-80 2P is a double-pole miniature circuit breaker rated up to 80A, used to protect single-phase circuits that require simultaneous switching of line and neutral. Typical uses include the main switch of a single-phase distribution board, protection for large single-phase appliances (electric showers, cookers, air conditioners, water heaters), sub-mains to outbuildings, and feeders to sub-panels. Because it opens both L and N, it provides full isolation for safe maintenance.

Why choose a 2P breaker instead of a 1P for a single-phase circuit? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 1P MCB switches only the line conductor and leaves neutral connected; a 2P switches both line and neutral together. Wiring regulations in many countries require double-pole isolation for main switches, and it is strongly recommended for circuits feeding equipment that may be touched or serviced. Even if neutral is not considered "live," a 2P breaker removes all voltage from the downstream circuit, preventing shock risk from crossed neutral or broken neutral faults.

What does "air" mean in the product description? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

"Air" means the breaker uses atmospheric air as the medium to extinguish the arc that forms when contacts open under fault current. Unlike oil or gas circuit breakers, an air MCB channels the arc through a stack of metal plates (arc chute) that split, cool, and de-ionize it until it can no longer sustain. This is the standard interruption method for low-voltage MCBs: simple, maintenance-free, and reliable over many operations.

What current ratings are available in the WSB9-80 2P range? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB9-80 frame is offered across a range of rated currents, commonly 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, and 80A, in B, C, and D trip curves. The 80A version is the top rating of the frame and is typically used as a main switch or heavy feeder, while the lower ratings serve final circuits such as sockets, lighting, and appliances. Confirm the available ratings and curves when ordering for a specific project.

How does the WSB9-80 2P protect against overload and short circuit? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Like other Westhomes MCBs, it uses a thermal-magnetic trip: a bimetallic strip bends slowly under mild overload to trip after an inverse time delay, and an electromagnetic solenoid releases near-instantly when a large short-circuit current flows. On a 2P device, both poles are mechanically cross-linked, so whichever pole senses the fault opens both contacts. This ensures the load is fully isolated whether the fault is between L and N or within the load.

Can the WSB9-80 2P be used on a 400V system? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Although it is a 2-pole device, its 230V/400V rating means it is built to IEC 60898-1 voltage standards. In practice, a 2P MCB is almost always used on a 230V single-phase circuit (L–N). Its internal insulation and separation are rated such that it can also be used across two phases of a 400V three-phase system in special applications, but this is unusual; for standard three-phase loads, select the 3P version. Always verify the system voltage and wiring configuration on the rating plate.

How is the WSB9-80 2P installed on a DIN rail? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It clips onto a standard 35mm DIN rail using the integrated rail catch. Open the front cover if accessible, hook the top edge onto the rail, and press the bottom until it clicks into place. Remove it by pulling the bottom release tab downward with a screwdriver. Connect the incoming L and N to the top terminals, and outgoing L and N to the bottom terminals, observing the correct polarity. Tighten to the specified torque and ensure the earth cable of the panel remains connected to the panel's earth bar.

Why does the WSB9-80 2P sometimes trip when an air conditioner starts? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Air conditioners and refrigeration compressors draw a locked-rotor starting current of 5–7 times running current for a fraction of a second. A B-curve MCB (instantaneous trip at 3–5 In) can see this as a short circuit and trip. The fix is usually to select a C-curve (5–10 In) or D-curve (10–20 In) breaker sized to the compressor FLA, rather than to the maximum cable rating. A properly sized C-curve WSB9-80 will ride through the starting inrush while still clearing a genuine short circuit.

Does the WSB9-80 2P support accessories such as auxiliary contacts or shunt trips? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Most WSB9-80 frames are designed to accept side- or front-mounting accessories such as auxiliary contacts (OF), fault-signal contacts (SD), shunt releases (SHT) for remote tripping, and undervoltage releases (UVR). These accessories snap onto the side or top of the breaker without changing its DIN-rail footprint. They are commonly used in commercial and industrial panels to provide remote status indication or emergency stop wiring. Confirm accessory compatibility when ordering.

What routine checks should be performed on a WSB9-80 2P main switch? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Once or twice a year, a qualified electrician should inspect the breaker for physical damage, check terminal torque, exercise the operating handle a few times, and verify that it trips freely without sticking. Because this breaker often sits at the origin of an installation carrying 63–80A, any discoloration, burning smell, or warmth on the case is a sign of a loose connection or overload and requires immediate investigation. After any short-circuit operation, the breaker should be inspected or replaced, even if it still appears functional.