WSB3L Series 1P+N 63A RCCB

The Westhomes WSB3L Series RCCB 1P+N 63A residual current circuit breaker is designed for high-safety performance in low-voltage AC systems operating at 230V/400V, 50Hz.

Social focus:

WSB3L Series 1P+N 63A RCCB | Mini Residual Current Circuit Breaker for 230V/400V AC

The Westhomes 1P+N 63A RCCB is a cost-effective, high-performance solution for secure electrical distribution, combining compact design, advanced protection, and easy installation for small-scale and medium-scale power systems.

With its 1P+N configuration and rated current of 63A, this miniature RCCB ensures swift disconnection during ground faults or leakage events to protect both people and connected equipment.

Ideal for modern electrical distribution networks, the WSB3L RCCB offers advanced functionality in a compact and durable design. Its high-sensitivity leakage detection triggers a rapid response to any abnormal current flows, preventing potential electric shocks, electrical fires, or system failures. Built with flame-retardant, impact-resistant materials, the product is both safe and long-lasting, suitable for installations where 1-pole protection with neutral is required.

This 1P+N 63A RCCB is widely used in residential buildings, commercial facilities, distribution boxes, and control cabinets, where both compact size and reliability are crucial. The device also supports overload and short circuit protection, making it a multifunctional solution for modern power safety management.

KEY INFORMATION

Rated Current 16, 20, 25, 32, 40, 50, 63A
Rated Voltage Ue AC240V (1P+N, 2P); AC400V (3P+N, 4P)
Rated Insulation Voltage Ui AC415
Rated Impulse Withstand Voltage Uimp 4kV
Rated Frequency 50/60Hz
Number of Poles 1P+N, 3P+N
Module Size 36mm, 72mm
Circuit Type AC type, A type, B type
Breaking Capacity 6000A, 10000A
Rated Residual Current I△n 10mA, 30mA, 100mA, 300mA
Rated Residual Operation Current 10, 30, 100, 300mA
Optimum Operation Temperature -5ºC to 40ºC
Terminal Tightening Torque 2.5-4N/m
Terminal Capacity (top) 25mm²
Terminal Capacity (bottom) 25mm²
Electro-mechanical Endurance 4000 cycles
Mounting 35mm DIN rail
The very new tripping structure makes more in safety
Suitable Busbar PIN busbar
Standard IEC61008-1

Basic Info.

Model NO. WSB3L
Arc-extinguishing Medium Air
Structure MCB
Type Circuit Breaker
Certification ISO9001-2000, CE, CB, CCC
Ka 6ka, 10ka
Voltage AC240V/AC400V
Specification 10A-63A
Origin China
Production Capacity 365000
Speed Normal Type Circuit Breaker
Installation Fixed
Poles Number 1p+N, 3p+N
Function Conventional Circuit Breaker,
Circuit-Breaker Failure Protection,
Overcurrent Protection,
OVP(Overvoltage Protection)
Production Line 100% Automic
Cooperation Type OEM ODM
Transport Package Standard
Trademark Westhomes
HS Code 8536300000

FREQUENTLY ASKED QUESTION (FAQ)

What is the WSB3L Series 63A RCCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB3L is a 1P+N residual current circuit breaker rated up to 63A, designed to detect earth-leakage currents and trip quickly to protect people and property. As an electronic-type RCCB, it uses an electronic amplifier and relay to evaluate the CT signal rather than a purely electromechanical trip. It must be paired with a separate MCB or fuse for over-current and short-circuit protection.

What does "1P+N 63A" mean? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

1P+N means the device switches the phase pole and also connects/disconnects the neutral pole, with sensing on the phase conductor. The 63A rating is the maximum continuous load current it can carry without tripping, suitable for typical domestic and light-commercial final circuits such as sockets and showers. It is intended for single-phase 230/240V 50/60Hz systems.

How does an electronic RCCB work internally? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A zero-sequence current transformer senses the residual current, then an electronic circuit amplifies and compares that signal against a reference; when it exceeds the sensitivity threshold (e.g., 30mA), a small relay energizes to release the main contacts. Because the electronics need a small supply to function, the WSB3L derives operating power from the line voltage. This is different from an electromagnetic RCCB, which is self-powered by the residual current itself.

What are the advantages of an electronic RCCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Electronic RCCBs can achieve higher sensitivity, more precise trip characteristics, and more compact dimensions than equivalent electromagnetic designs, often at a lower cost. They can also integrate additional features such as adjustable sensitivity, time delay, or communication. This makes them well suited to modern boards where space and features matter.

What are the disadvantages of an electronic RCCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Because it relies on an internal electronic supply, an electronic RCCB may not trip if the supply voltage is lost (e.g., if the neutral is broken while the phase remains live, or during a zero-volt fault condition). It is also more sensitive to electrical transients and voltage spikes. For this reason, applications requiring fully self-powered, fail-safe protection may specify an electromagnetic type.

How is the WSB3L installed? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Clip it onto a 35mm DIN rail in a dry distribution board, connect the incoming phase and neutral to the marked line terminals and the outgoing circuit to the load terminals. Ensure both conductors pass through the internal CT and that the device's auxiliary supply connection is present so its electronics are powered. Torque the terminals per the datasheet and pair with an MCB of the appropriate rating for the protected circuit.

How do I test it? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Press the integrated test ("T") button monthly to verify the trip mechanism and electronics respond. Because it is electronic, also check that the device is correctly supplied (the phase/neutral supply to its electronics is present), since a missing supply prevents proper function. If the test button fails to trip it, replace the unit.

Which standard does it meet? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB3L is designed to IEC 61008 (residual current operated circuit-breakers without integral over-current protection), including requirements for electronic devices within that standard. CE marking confirms conformity with applicable directives. Note that IEC 61008 includes specific provisions for electronic RCCBs regarding supply-voltage dependence.

What troubleshooting should I do if it trips repeatedly? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Disconnect loads one by one to isolate the circuit with earth leakage; check for damp insulation, long buried cables, surge protective devices, and electronic loads producing leakage. Verify the device is correctly supplied, and consider upgrading to Type A if pulsating DC leakage is suspected. If nuisance tripping persists, install a delayed/selective (S) type upstream so the 30mA device can discriminate.

Where is the WSB3L 63A typically used? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is commonly used in residential single-phase distribution boards as earth-leakage protection for socket circuits, bathrooms, kitchens, and outdoor supplies. Its compact size and 63A rating also suit light-commercial sub-boards and modular furniture/pod installations. It should not be used where a fully self-powered, fail-safe electromagnetic RCCB is mandated by the local wiring code.