Westhomes WSB1L Series 125A 2P RCCB

The Westhomes WSB1L Series 125A 2P RCCB (Residual Current Circuit Breaker) is a high-performance safety solution designed for modern low-voltage distribution systems.

Social focus:

WSB1L Series 125A 2P RCCB | Residual Current Circuit Breaker with Overload Protection

With its compact footprint and intelligent safety features, the WSB1L 125A 2P RCCB offers the optimal balance of protection, durability, and ease of installation, making it a top choice for global electrical distribution markets.

WSB1L

Engineered for AC 50Hz networks with a rated working voltage of AC240/400V, this 2-pole RCCB supports current ratings up to 125A, offering enhanced protection against overload, short circuits, and leakage faults.

When abnormal leakage current or personal electric shock occurs, this 125A 2P RCCB can rapidly disconnect the power supply within milliseconds, ensuring the safety of personnel and electrical equipment. It is an essential protective device for residential, commercial, and industrial power distribution systems.

Manufactured with an advanced internal structure, the WSB1L series features a compact design, high-impact-resistant housing, and flame-retardant materials, ensuring long-lasting reliability even under harsh operating conditions. This miniature circuit breaker is ideal for distribution boxes, panel boards, and branch circuit protection where safety and performance are critical.

KEY INFORMATION

Rated Current 16, 20, 25, 32, 40, 50, 63A
Rated Voltage Ue AC240V (1P+N, 2P); AC400V (3P+N, 4P)
Rated Insulation Voltage Ui AC415
Rated Impulse Withstand Voltage Uimp 4kV
Rated Frequency 50/60Hz
Number of Poles 1P+N, 3P+N
Module Size 36mm, 72mm
Circuit Type AC type, A type, B type
Breaking Capacity 6000A, 10000A
Rated Residual Current I△n 10mA, 30mA, 100mA, 300mA
Rated Residual Operation Current 10, 30, 100, 300mA
Optimum Operation Temperature -5ºC to 40ºC
Terminal Tightening Torque 2.5-4N/m
Terminal Capacity (top) 25mm²
Terminal Capacity (bottom) 25mm²
Electro-mechanical Endurance 4000 cycles
Mounting 35mm DIN rail
The very new tripping structure makes more in safety
Suitable Busbar PIN busbar
Standard IEC61008-1

Basic Info.

Model NO. WSB1L
Arc-extinguishing Medium Air
Structure MCB
Type Circuit Breaker
Certification ISO9001-2000, CE, CB, CCC
Ka 6ka, 10ka
Voltage AC240V/AC400V
Specification 10A-63A
Origin China
Production Capacity 365000
Speed Normal Type Circuit Breaker
Installation Fixed
Poles Number 1p+N, 3p+N
Function Conventional Circuit Breaker,
Circuit-Breaker Failure Protection,
Overcurrent Protection,
OVP(Overvoltage Protection)
Production Line 100% Automic
Cooperation Type OEM ODM
Transport Package Standard
Trademark Westhomes
HS Code 8536300000

FREQUENTLY ASKED QUESTION (FAQ)

What is a 2P RCCB and how does it work on a single-phase supply? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 2P RCCB is a single-phase residual current device that switches both the line (L) and neutral (N) conductors together while monitoring their vector sum through a toroidal current transformer. Under normal conditions the outgoing line current equals the returning neutral current, so no residual flux is detected. Any current leaking to earth — through a person or damaged insulation — creates an imbalance that triggers the trip solenoid and opens both poles simultaneously.

What does the "2P" designation mean for wiring? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

"2P" means the device has two poles that switch both line and neutral, so it fully isolates the load from the supply rather than switching only the hot conductor. Incoming L and N land on the supply-side terminals, and the same L and N exit on the load side. The PE conductor must never pass through the toroid and must never be switched; it runs continuously from the main earthing terminal to all exposed conductive parts.

What does the 125A rating mean, and why is it higher than typical household RCCBs? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The 125 A is the rated current (In) — the maximum continuous current each pole can carry at rated ambient temperature without overheating. Household RCCBs are commonly 40–63 A, so the 125 A rating positions this WSB1L unit as a high-current single-phase device suitable for a main incomer or large single-phase feeder. As with all RCCBs, it does not protect against overload or short circuit; an upstream MCB or MCCB must provide that backup.

What residual sensitivity is used, and is 30 mA still appropriate at 125 A? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 30 mA IΔn is still the standard value for human protection, regardless of the rated current: sensitivity depends on the leakage level needed to protect a person, not on how much current the load draws. At 125 A the unit may feed large single-phase loads such as industrial heaters, shops, or small workshops, so the designer should also check the steady-state leakage of the installation; if it is high, a 100 mA or S-type device may be preferred for the main incomer, with 30 mA RCCBs used downstream for socket-outlet circuits.

Type AC vs Type A — which should I choose for a 125A single-phase installation? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Type AC detects only sinusoidal AC residual current, while Type A also detects pulsating DC residual current produced by rectifier and electronic loads. A 125 A single-phase feeder typically supplies shops, offices, or workshops that contain computers, LED drivers, variable-speed compressors, and battery chargers, so a Type A WSB1L is generally the safer specification. Pure Type AC is acceptable only when the load is purely resistive, such as a simple heating installation.

How is the WSB1L 125A 2P mounted on a DIN rail? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It clips onto a standard 35 mm DIN rail in a distribution enclosure, typically occupying two pole-widths (though a 125 A body is physically larger than a 63 A unit, so confirm the required pole-space in the datasheet). Connect L and N to the marked supply-side terminals, route the load-side L and N to the outgoing bars, tighten conductors to the nameplate torque (typically 2.5–4 N·m for 125 A), and keep the PE wire outside the device. Verify rail load rating — a 125 A RCCB is heavy, so the DIN rail and enclosure must be rated accordingly.

What is the test button for, and how do I maintain the unit? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The test button injects a simulated residual current so you can confirm the trip mechanism operates; press it monthly with the circuit energized and the unit should trip instantly. If it fails to trip, replace the device immediately. Beyond testing, inspect terminals annually for tightness, check for discoloration or overheating, and keep the enclosure dry and dust-free. RCCBs have no user-serviceable parts; never attempt to open or repair the internal toroid or solenoid.

Why does a 125A 2P RCCB nuisance-trip on long or heavily loaded single-phase circuits? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Large single-phase feeders often run long cable lengths, which have significant distributed capacitance between conductors and earth; this steady capacitive leakage can drift above 30 mA when many loads are switched on, especially at start-up. Switching power supplies and LED drivers also generate high-frequency leakage that can exceed the trip threshold of a Type AC device. Mitigate by using Type A or F units, selecting a higher IΔn for the main feeder, or using a time-delayed S-type to coordinate with downstream 30 mA RCCBs.

Which standards and certifications apply? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WSB1L 125 A 2P RCCB is designed to IEC 61008-1, the product standard for residual current circuit breakers without integral overcurrent protection, covering tripping characteristics, conventional operating and non-operating residual currents, and endurance. The CE mark indicates conformity with the EU LVD and EMC directives. Local wiring rules still dictate installation practice, including maximum disconnection times, discrimination between upstream and downstream RCCBs, and the required sensitivity for particular circuits.

How is this 125A 2P RCCB different from an RCBO or MCB, and what are typical applications? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

An MCB provides only overload/short-circuit protection, an RCCB provides only earth-leakage protection, and an RCBO combines both. The WSB1L 125 A 2P is therefore used as a high-current single-phase earth-leakage head, with upstream or downstream overcurrent devices providing fault protection. Common applications include main incomers for small shops and offices, large single-phase industrial heaters, welding outlets, car wash bays, telecom shelters, and retrofit upgrades where an existing single-phase installation needs 30 mA protection without redesigning the whole board.