OEM/ODM MCCB WCM8E-125M | AC Molded Case Circuit Breaker

The WCM8E-125M Molded Case Circuit Breaker (MCCB) is a state-of-the-art solution designed for reliable electrical protection in commercial, industrial, and marine applications.

Social focus:

OEM/ODM AC Molded Case Circuit Breaker WCM8E-125M | MCCB with Short Circuit Protection

With a rated insulation voltage of 800V and a compact design, the WCM8E-125M provides comprehensive circuit protection against overload, short circuit, and under-voltage scenarios.

WCM8E-125M

WCM8 series moulded case circuit breakers are available in four different breaking capacity classes: C-type (low), L-type (standard), M-type (high) and H-type (extra high), ensuring customised solutions based on different short-circuit breaking capacity (Icu) requirements.

It is designed to protect distribution lines and connected electrical equipment from damage, thereby improving system reliability and safety.

Adopting internationally advanced design and manufacturing technology, this moulded case circuit breaker performs well in environments where infrequent line switching or motor starting is required at AC 50Hz, with a rated working voltage of up to 690V, making it ideal for switchboards, motor control centres, industrial machinery and marine power systems.

Its rugged structure and customizable configuration make it ideal for OEM/ODM electrical solutions that require high reliability and space efficiency.

WCM8E electronic type
WCM8E terminal
WCM8E technical data
WCM8E linger lifespan

KEY INFORMATION

Model Frame level rated current (A) Current Rating (A) Rated operation voltage (V) Rated insulation voltage (V) Rated ultimate short circuit breaking capacity (kA) 400V Rated operation short circuit breaking capacity (kA) 400V
WCM8-63L 63 (6), 10, 16, 20, 25, 32, 40, 50, 63 AC400 AC500 25 18
WCM8-63M 50 35
WCM8-125C 100 (10), 16, 20, 25, 32, 40, 50, 63, 80, 100 AC690 AC800 20 10
WCM8-125L 35 17.5
WCM8-125M 50 35
WCM8-125H 85 50
WCM8-250L 225 100, 125, 140, 160, 180, 200, 225 AC690 AC800 35 18
WCM8-250M 50 35
WCM8-250H 85 50
WCM8-400L 400 225, 250, 315, 350, 400 AC690 AC800 50 25
WCM8-400M 65 42
WCM8-400H 100 65
WCM8-630L 630 400, 500, 630 AC690 AC800 50 25
WCM8-630M 65 42
WCM8-630H 100 65
WCM8-800M 800 630, 700, 800 AC690 AC800 75 50
WCM1-800H 100 65
WCM8-1250 800 1000, 1250 AC690 AC800 65 40
WCM8-2000 1250 1400, 1600, 1800, 2000 AC690 AC800 65 40
Description Specification
Frame level rated current Inm(A) 63 125 250 400 630 800 1250
Breaking the capacity level L M C L M H L M H L M H L M H M H
Overall Dimensions
(mm)
Overall Dimensions
W 75/103 65/93/107 74.5/107/142 150/198;定140/184 182/238 210/280 210/280
L 136 150 165 257;定257 270 280 466
H 66.5 61 79 81 99 102;定108 105.5 107.5 139
H1 90.5 86 104 110 127 151.5;定146 155 155 190
Mounting Dimensions
(mm)
Mounting Dimensions
A 25 30 35 44/90;定44/88 58 70 70
B 115 130.5 126 194;定215 200 243 300
Φd 3.5 4.5 5 7;定6.5 7 7 9.5

Basic Info.

Model NO. WCM8E-125M
Arc-extinguishing Medium Air
Structure MCCB
Type Circuit Breaker
Certification ISO9001-2000, CE, CB, CCC
Factory Own
Payment L/C, T/T, D/P, Western Union, Paypal, Money Gram
Specification 10A-800A
Origin China
Production Capacity 5000PCS/Week
Speed High-Speed Circuit Breaker
Installation Fixed
Poles Number 3p, 4p
Function Conventional Circuit Breaker,
Circuit-Breaker Failure Protection,
Overcurrent Protection,
OVP(Overvoltage Protection)
Production Line 100% Automic
Cooperation Type OEM ODM
Transport Package Paper Box
Trademark Westhomes
HS Code 8536200000

For a closer look at circuit breaker, read Breakers Electrical: Understanding Circuit Breakers.

For a closer look at circuit breaker, read WM-RT Thermomagnetic double adjustable molded case circuit breaker.

For a closer look at circuit breaker, read Westhomes 4 Pole MCCB Price Low Voltage AC Molded Case Circuit Breaker.

For a closer look at circuit breaker, read Manufacture Electric Type Fixed MCCB Circuit Breaker 3p 630A Molded Case Circuit Breaker.

FREQUENTLY ASKED QUESTION (FAQ)

What is the WCM8E-125M and what does its 125A rating mean? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WCM8E-125M is an AC molded case circuit breaker rated up to 125A, used to protect low-voltage distribution circuits from overload and short circuit. The 125A is the maximum continuous current it can carry, making it suitable for sub-mains, motor control centers, and machine tool panels. It interrupts AC fault currents in 50/60Hz systems up to its rated operational voltage.

What OEM/ODM customization options are typically available? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Through OEM/ODM programs, buyers can request custom brand labeling and logos, tailored rated current and trip settings, specific pole configurations (1P/2P/3P/4P), fitted accessories (shunt/undervoltage releases, auxiliary contacts, motor operator), and customized packaging or manual. Packaging, barcodes, and technical nameplate data can also be adapted to a customer's brand and target market certifications. This allows the breaker to be resold under a private label or integrated into an OEM switchboard.

How does the thermal-magnetic trip unit operate? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A bimetal strip heats up under sustained overload and bends to release the mechanism after an inverse-time delay, while an electromagnet picks up quickly on very high fault current for near-instantaneous tripping. This dual-action protects against both long-term mild overload and destructive short circuits. The WCM8E-125M's trip characteristics are set per IEC 60947-2 to provide predictable coordination.

What breaking capacity should I expect and how is it chosen? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Breaking capacity (Icu) for a 125M-class MCCB is commonly in the 10kA–25kA range depending on model. It must be at least equal to the maximum prospective short-circuit current available at the installation point. A higher Icu gives more margin and better selectivity with downstream MCBs. Always verify the rated value on the nameplate against the calculated short-circuit level before installation.

How should cables be connected to a 125A MCCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Connect supply to the line terminals and load to the load terminals using appropriately sized lugs (roughly 25–70 mm² copper depending on current and derating), tightening to the stated torque. Keep cable bends smooth near the terminals and do not stress them mechanically. If reversing supply and load is allowed by the datasheet, note that some accessories' sensing may then require re-checking; otherwise observe the marked line/load direction.

Can it protect motors, and what curve should be used? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes, the WCM8E-125M can be used as a motor circuit protector, typically with a Type M (motor) instantaneous setting so inrush current during start-up does not trip it. It provides short-circuit and earth-fault protection, while a separate thermal overload relay in the contactor starter protects the motor during running overload. Set the instantaneous pick-up above the motor's locked-rotor current to avoid nuisance tripping on start.

Which standards and certifications apply? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The breaker is designed to IEC 60947-2 for low-voltage circuit breakers, with CE marking for the European market and other regional marks (e.g., UL, CCC, KEMA) available on request through OEM/ODM. The standard defines trip classes, utilization categories, and dielectric and endurance tests. Certification documents and type-test reports are normally available to qualified distributors and OEM partners.

What maintenance is recommended over its service life? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Visually inspect for cracks, discoloration, or operation handle wear; re-torque terminals periodically; and exercise the trip mechanism manually. If the breaker has cleared a substantial short-circuit fault, it should be inspected or replaced even if it resets, because contacts and the arc chute may be damaged. Keep the molded case clean and dry and never oil or modify internal parts.

Why choose an MCCB over an MCB at 125A? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

At 125A, MCBs are at the upper end of their range and typically have fixed trips and lower breaking capacity, while the WCM8E-125M offers higher short-circuit rating, adjustable trip settings, and accessory options. MCCBs are also more robust and easier to coordinate with upstream/downstream devices. For feeder or motor circuits where selectivity and future flexibility matter, an MCCB is the standard choice.

Why should a buyer consider an OEM/ODM program for this breaker? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

An OEM/ODM program lets a brand differentiate itself with its own logo, nameplate, packaging, and selected current/trip options without developing a product from scratch. It also allows batch-specific certification adaptation for target regions and consistent build quality across repeat orders. This reduces time-to-market and inventory complexity for switchgear builders, panel manufacturers, and distributors.

RELATED PROJECTS

REQUEST
YOUR FREE QUOTE

* indicates a required field