WNB1-63 3P MCB 6kA Three Pole Circuit Breaker

Get the Westhomes WNB1-63 3P MCB. 415V three-phase protection with 6kA breaking capacity. Perfect for motors and pumps. B/C/D curves. DIN rail.

Social focus:

WNB1-63 3P MCB 6kA Three Pole Circuit Breaker  | B/C/D Curve for Motors

Westhomes WNB1-63 3P Miniature Circuit Breaker – Robust Protection for Three-Phase Commercial and Light Industrial Loads.

Designed for three-phase systems, the Westhomes WNB1-63 3P MCB delivers reliable protection for motors, pumps, and small machinery. This triple-pole breaker simultaneously monitors and protects all three phases (L1, L2, L3) against the damaging effects of overloads and short circuits.

Key Features:

Three-Phase Control: Switches and protects all three live conductors, ensuring balanced protection across the entire system .

6kA Breaking Capacity: Provides ample short-circuit protection for commercial environments, safely quenching electrical arcs up to 6kA.

Application-Specific Curves:

  • C Curve: Ideal for general three-phase loads like distribution sub-panels.
  • D Curve: Specifically designed to handle high inrush currents from small three-phase motors, transformers, and inductive loads.

Standard Integration: 18mm per pole width, compatible with all standard 35mm DIN rail enclosures.

Rated Voltage: Optimized for 415V AC 3-phase systems at 50/60Hz.

Applications

Three-phase lighting circuits, small water pumps, conveyor systems, compressors, and HVAC equipment.

Key attributes

Type MCB
BCD Curve B, C, D
Rated Frequency (Hz) 50hz/60hz
Material Copper
Application Circuit-Breaking
Model Number WNB1-63 Series

Rated Voltage 220V/230V, 400 V
Breaking Capacity 6 kA
Mounting Type Rail Mounting
Protection Li
Place of Origin Zhejiang, China
Brand Name Westhomes

Standard IEC/EN 60898-1
Protection Overcurrent and short circuit
Type of trip Thermo-magnetic
No.of poles 1P,1P+N,2P,3P,3P+N,4P
Rated currents(In) 1,2,3,4,5,6,8,10,16,20,25,32,40,50,63A
Rated voltage(Ue) 240/415V~
Rated frequency 50/60Hz
Rated breaking capacity 3KA,4.5KA,6KA.
Rated impulse withstandard voltage(1,5/50)Uimp 4,000V
Dielectric test voltage at Ind.Freq.for 1 min 2kV
Thermal release characteristic (1.13-1.45)x In
Magnetic release characteristic B:(3-5)x In,C:(5-10)x In,D:(10-20)x In
Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Yes
Protection degree IP20
Ambient temperature -5℃ to+40℃,Max.95%humidity
Terminal connection type Cable/Pin-type busbar
Installation Mounting on 35mm DIN rail
Connection From top and bottom

Packaging and delivery

Selling Units Single item

Lead time

Quantity (pieces) 1 – 1,000 > 1,000
Lead time (days) 15 To be negotiated

Related: 32 Amp miniature circuit breaker Applications, which covers miniature circuit step by step.

FREQUENTLY ASKED QUESTION (FAQ)

What is a 3P MCB and what circuits does it protect? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A three-pole MCB is a DIN-rail breaker that switches and protects the three phase conductors (L1, L2, L3) of a three-phase circuit on a single handle. It is used to protect three-phase loads such as motors, heaters, three-phase sockets, and branch feeders in commercial and industrial distribution boards.

What does the 6 kA breaking capacity mean for three-phase faults? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The 6 kA rating means the breaker can safely interrupt a prospective short-circuit current of up to 6000 A. In a three-phase system a bolted fault can reach very high currents near the transformer, so the 6 kA rating must be at least the calculated fault level at the breaker's position; otherwise the breaker may be destroyed on a major fault.

How does the WNB1-63 3P MCB work internally? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Inside, a thermal bimetallic strip provides delayed overload protection, and an electromagnetic solenoid provides instantaneous short-circuit tripping. All three poles are mechanically coupled so that an overload or short on any phase opens all three phases simultaneously, with the arc contained and cooled in internal arc chutes.

Which tripping curve should I choose for motors? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

For direct motor starting with high locked-rotor current, a Type C or D curve is normally used to tolerate the starting inrush without nuisance tripping. Type D trips at a higher multiple (roughly 10–20× In) for the heaviest inrush, while Type C (roughly 5–10× In) suits lighter motor and general three-phase loads — match the curve to the actual starting current.

Where does the neutral go on a 3P MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 3P MCB does not switch or protect the neutral; the neutral is connected directly to the neutral busbar, and the protective earth goes to the earth bar. Only the three phases pass through the breaker, which is why this device is used when the neutral should remain continuous and unswitched.

How do I select the ampere rating? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Work out the three-phase load's full-load current, size the phase conductors to carry it, and choose an In above the design current but within the cable ampacity. Add derating for ambient temperature and grouping, and select the B/C/D curve according to the load's inrush characteristics.

How is it mounted and wired? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Snap the WNB1-63 onto a standard 35 mm DIN rail in the board, connect the three incoming phases to the line terminals and the outgoing phases to the load terminals (observing the marked direction), and tighten each terminal to the datasheet torque. Leave the supply isolated until wiring is complete and polarity/phase labels are checked.

Why is breaking-capacity selection critical near a transformer? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Available short-circuit current rises sharply close to a large transformer and short, low-impedance cables. A 6 kA breaker must not be used where the calculated fault current exceeds 6 kA, or it may fail to clear — for very high-fault locations you need a higher kA rating or upstream discrimination/coordination.

What are common troubleshooting steps? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

If the breaker trips, first determine whether it was an overload (thermal trip, delayed) or a short circuit (instantaneous trip). Remove loads to test for overloading, inspect for a faulted three-phase appliance or damaged cables, and check loose or overheated terminals. Do not reclose repeatedly if a fault remains.

What certification and standard apply? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

As a low-voltage MCB, the WNB1-63 3P unit is designed to IEC 60898-1 and typically carries CE marking. Refer to the product datasheet for its exact rated current, breaking capacity (6 kA), and trip-curve options to confirm they match the intended three-phase application.

RELATED PROJECTS

REQUEST
YOUR FREE QUOTE

* indicates a required field