WNB1-63 3P MCB 6kA Three Pole Circuit Breaker

Get the Westhomes WNB1-63 3P MCB. 415V three-phase protection with 6kA breaking capacity. Perfect for motors and pumps. B/C/D curves. DIN rail.

Social focus:

WNB1-63 3P MCB 6kA Three Pole Circuit Breaker  | B/C/D Curve for Motors

Westhomes WNB1-63 3P Miniature Circuit Breaker – Robust Protection for Three-Phase Commercial and Light Industrial Loads.

Designed for three-phase systems, the Westhomes WNB1-63 3P MCB delivers reliable protection for motors, pumps, and small machinery. This triple-pole breaker simultaneously monitors and protects all three phases (L1, L2, L3) against the damaging effects of overloads and short circuits.

Key Features:

Three-Phase Control: Switches and protects all three live conductors, ensuring balanced protection across the entire system .

6kA Breaking Capacity: Provides ample short-circuit protection for commercial environments, safely quenching electrical arcs up to 6kA.

Application-Specific Curves:

  • C Curve: Ideal for general three-phase loads like distribution sub-panels.
  • D Curve: Specifically designed to handle high inrush currents from small three-phase motors, transformers, and inductive loads.

Standard Integration: 18mm per pole width, compatible with all standard 35mm DIN rail enclosures.

Rated Voltage: Optimized for 415V AC 3-phase systems at 50/60Hz.

Applications

Three-phase lighting circuits, small water pumps, conveyor systems, compressors, and HVAC equipment.

Key attributes

Type MCB
BCD Curve B, C, D
Rated Frequency (Hz) 50hz/60hz
Material Copper
Application Circuit-Breaking
Model Number WNB1-63 Series

Rated Voltage 220V/230V, 400 V
Breaking Capacity 6 kA
Mounting Type Rail Mounting
Protection Li
Place of Origin Zhejiang, China
Brand Name Westhomes

Standard IEC/EN 60898-1
Protection Overcurrent and short circuit
Type of trip Thermo-magnetic
No.of poles 1P,1P+N,2P,3P,3P+N,4P
Rated currents(In) 1,2,3,4,5,6,8,10,16,20,25,32,40,50,63A
Rated voltage(Ue) 240/415V~
Rated frequency 50/60Hz
Rated breaking capacity 3KA,4.5KA,6KA.
Rated impulse withstandard voltage(1,5/50)Uimp 4,000V
Dielectric test voltage at Ind.Freq.for 1 min 2kV
Thermal release characteristic (1.13-1.45)x In
Magnetic release characteristic B:(3-5)x In,C:(5-10)x In,D:(10-20)x In
Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Yes
Protection degree IP20
Ambient temperature -5℃ to+40℃,Max.95%humidity
Terminal connection type Cable/Pin-type busbar
Installation Mounting on 35mm DIN rail
Connection From top and bottom

Packaging and delivery

Selling Units Single item

Lead time

Quantity (pieces) 1 – 1,000 > 1,000
Lead time (days) 15 To be negotiated

FREQUENTLY ASKED QUESTION (FAQ)

What is the WNB1-63 3P MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The Westhomes WNB1-63 3P MCB is a three-pole miniature circuit breaker designed for three-phase low-voltage electrical systems. It provides thermomagnetic protection against overloads and short circuits across three phase conductors, making it suitable for commercial and light industrial applications.

What does 3P mean on an MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

3P means the circuit breaker has three poles and is designed to switch and protect three phase conductors, typically L1, L2, and L3. It is commonly used in three-phase systems where a neutral conductor does not need to be switched.

What is the breaking capacity of the WNB1-63 3P MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WNB1-63 series is available with a rated short-circuit breaking capacity of up to 6kA. The appropriate breaking capacity should be selected according to the prospective short-circuit current at the installation point.

What is the rated current range of the WNB1-63 3P MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WNB1-63 series provides multiple rated current options from 1A to 63A, including 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, and 63A. The correct rating should be selected according to the load current and cable carrying capacity.

What voltage is the WNB1-63 3P MCB suitable for? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WNB1-63 series has a rated operational voltage of 240/415V AC and operates at 50/60Hz, making it suitable for common three-phase low-voltage distribution systems.

What are the B, C, and D curves of the WNB1-63 MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WNB1-63 series is available with B, C, and D magnetic tripping characteristics:

B Curve: 3–5 × In

C Curve: 5–10 × In

D Curve: 10–20 × In

B curve is generally suitable for low-inrush loads, C curve for general-purpose loads, and D curve for high-inrush loads such as motors and transformers.

Is the WNB1-63 3P MCB suitable for three-phase motors? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Yes. The WNB1-63 3P MCB can be used for three-phase motor applications. For motors with high starting currents, the D-curve version is generally more suitable because its magnetic tripping range is higher and can help reduce nuisance tripping during motor startup.

What is the difference between a 3P and 4P MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 3P MCB protects and switches three phase conductors, while a 4P MCB adds a fourth pole for the neutral conductor. A 3P breaker is generally suitable when only the three phases need to be switched, while a 4P configuration may be selected when neutral switching or isolation is required.

How is the WNB1-63 3P MCB installed? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The WNB1-63 is designed for installation on a standard 35mm DIN rail, making it suitable for modular distribution boards and electrical switchgear. It supports cable and pin-type busbar connections, with terminals that can be connected from the top or bottom.

How do I choose the right WNB1-63 3P MCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Selection should consider the system voltage, load current, cable capacity, prospective short-circuit current, load characteristics, and required tripping curve. The rated current should be coordinated with the protected cable, while the 6kA breaking capacity must be suitable for the available fault current.

For general three-phase loads, a C-curve version is commonly considered. For motors, pumps, transformers, and other high-inrush loads, a D-curve version may be more appropriate.