Popular Intelligent Air Circuit Breaker up to 690V 3p/4p ODM/OEM High Cost Performance Acb

WCW1 series MCB is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

Social focus:

WCW1 Moulded case circuit breaker

WCW1 is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

WCW1 series intelligent univeral circuit breaker (circuit breaker for short) applies at distribution network of AC 50Hz, rated voltage upto 600V( 690V), rated current 200A to 6300A, to distribute power and protect line and power supply equipments from fault demage of overload, under voltage, short circuit, single phase grounding. The circuit breaker has function of intelligent Protection with accurate
selection to increase power supply reliability ths to avoid unnecessary power cut. It has open communication interface to make “Four-remote type Control” to fulfill requirements of control center and automatic system. The circuit breakers’ impulse withstand voltage is 8000V when at altitude 2000 meter (Clarity according to standards of different altitude not over 12000V.)

KEY INFORMATION

WCW1

Pole  1P, 2P, 3P, 4P
Voltage  AC400V/690V
kA  10, 20, 30, 40, 60, 80, 100
Inm  1000A, 2000A, 3200A, 6300A
In  200A-6300A

MAIN TECHNICAL DATA

Frame level rated current Inm (A) Rated current In (A)
1000 200, 400, 630, 800, 1000
2000 630, 800, 1000, 1250, 1600, 2000
3200 2000, 2500, 2900, 3200
4000 3200, 3600, 4000
6300 4000, 5000, 6300

Related: ACB vs MCCB: Selection Guide for Main Incomers, which covers air circuit breaker step by step.

FREQUENTLY ASKED QUESTION (FAQ)

What is an intelligent air circuit breaker (ACB)? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

An intelligent ACB is a low-voltage air circuit breaker that uses an electronic (microprocessor) trip unit instead of a thermal-magnetic trip. It provides precise, adjustable protection plus metering, communication, and diagnostic functions, typically used as the main incoming breaker in switchgear.

What is the microprocessor/electronic trip unit? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

The trip unit samples current (and often voltage) continuously and computes thermal and magnetic protection curves digitally. It offers adjustable long-time, short-time, and instantaneous settings, plus earth-fault protection, and it records trips and measurements for analysis.

What voltage and current ratings are offered? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

This ACB is rated up to 690 V AC, covering both 400 V/415 V distribution and higher 690 V industrial systems. Frame sizes extend to 630 A and above, so it can be selected to match the capacity of the main or sub-main distribution.

What do 3P and 4P mean? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A 3P breaker switches and protects the three phase conductors only, while a 4P breaker also switches the neutral. Choose 4P where neutral isolation is required by the earthing scheme or by safety/maintenance requirements, otherwise 3P is standard.

What is the difference between drawout and fixed versions? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

A drawout ACB can be racked out to a test or isolated position without disconnecting the main busbars, making maintenance and replacement easier. A fixed version is bolted directly in place and is simpler and lower cost but requires isolation from upstream equipment for service.

What ODM/OEM customization is available? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

As an ODM/OEM product, the ACB can be customized in ratings, auxiliary contacts, trip-unit options, communication modules, labeling, and branding to fit your switchgear project. This allows integrators to match the breaker to specific panel designs and customer specifications.

What certifications does it carry? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is offered with CB, CE, ISO, and CCC type approvals. These mark compliance with international safety, EMC, quality-system, and Chinese national mandatory certification requirements, easing market entry and project tendering.

Which IEC standard applies? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

It is designed and tested to IEC 60947-2 (Low-voltage switchgear and controlgear—Circuit-breakers), which defines the ratings, protective characteristics, and short-circuit performance for circuit breakers.

How does an ACB compare with an MCCB? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

An ACB handles higher current and short-circuit levels, offers drawout flexibility and extensive adjustable protection/communication, and is used for main incoming. An MCCB is smaller, lower cost, and used for feeder and branch circuits. For the main switchboard, an ACB is the typical choice.

What are the main applications? plus-square Created with Sketch Beta. minus-square Created with Sketch Beta.

Intelligent ACBs serve as main incoming breakers, bus-tie, and large feeder protection in industrial plants, commercial buildings, hospitals, data centers, and power distribution substations where selectivity, monitoring, and high breaking capacity are required.