WCW1 Moulded case circuit breaker
WCW1 is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.
Get quick appointment for technical support!
WCW1 series MCB is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.
WCW1 is one of updated type MCCBs researched and developed by the company by using advanced design and manufacture technology internationally.

WCW1 series intelligent univeral circuit breaker (circuit breaker for short) applies at distribution network of AC 50Hz, rated voltage upto 600V( 690V), rated current 200A to 6300A, to distribute power and protect line and power supply equipments from fault demage of overload, under voltage, short circuit, single phase grounding. The circuit breaker has function of intelligent Protection with accurate
selection to increase power supply reliability ths to avoid unnecessary power cut. It has open communication interface to make “Four-remote type Control” to fulfill requirements of control center and automatic system. The circuit breakers’ impulse withstand voltage is 8000V when at altitude 2000 meter (Clarity according to standards of different altitude not over 12000V.)
| Pole | 1P, 2P, 3P, 4P |
| Voltage | AC400V/690V |
| kA | 10, 20, 30, 40, 60, 80, 100 |
| Inm | 1000A, 2000A, 3200A, 6300A |
| In | 200A-6300A |
| Frame level rated current Inm (A) | Rated current In (A) |
| 1000 | 200, 400, 630, 800, 1000 |
| 2000 | 630, 800, 1000, 1250, 1600, 2000 |
| 3200 | 2000, 2500, 2900, 3200 |
| 4000 | 3200, 3600, 4000 |
| 6300 | 4000, 5000, 6300 |

See Westhomes New Design DIN Rail Fixed Circuit Breaker Wcm7EL 35ka-85ka ODM OEM 1-4p for a deeper dive into circuit breaker.
See Westhomes Electric Shines at Middle East Energy Dubai 2025 for a deeper dive into circuit breaker.
See Westhomes Factory DIN Rail Wsb9sz-125II Low Voltage Circuit Breakers 1p+N for a deeper dive into circuit breaker.
See Westhomes Factory Miniature AC Low Voltage Circuit Breaker 3p with AC230V400V 50Hz/60Hz for a deeper dive into circuit breaker.
See Westhomes Wsb9-80 Miniature Air Low Voltage Circuit Breaker 2p with AC230V400V 50Hz/60Hz for a deeper dive into circuit breaker.
The 630A refers to the rated current of the breaker frame/trip setting, meaning it can carry and protect circuits up to 630 A continuously under specified conditions. It is selected to match the load current of the installation with appropriate overload and short-circuit protection.
LSI stands for Long-time, Short-time, and Instantaneous protection. Long-time trips on overloads with an inverse curve, short-time provides delayed short-circuit discrimination, and instantaneous trips immediately on severe faults. Together they enable selective coordination with downstream devices.
Yes, the intelligent trip unit typically adds earth-fault (ground-fault) protection on top of LSI, sensing residual current to protect against insulation faults and reduce shock and fire risk. The earth-fault threshold and delay are adjustable.
Optional communication modules such as Modbus (RTU/TCP) or Profibus allow the ACB to send measurements, status, and trip records to a SCADA or building management system. This supports remote monitoring and predictive maintenance.
CB indicates IEC scheme test certification, CE marks EU conformity, ISO confirms the quality-management system, and CCC is China's compulsory product certification. Together they demonstrate the breaker meets multiple national and international compliance regimes.
It is installed on the main vertical busbars in a low-voltage switchboard, either fixed bolted or in a drawout cassette. Proper ventilation, minimum phase spacing, and upstream/downstream coordination settings must be respected during installation.
Beyond fixed protection, it measures current and voltage, displays settings and metering, logs trip events, supports communication, and allows protection curves to be adjusted to the installation—rather than the fixed thermal-magnetic behavior of a basic breaker.
It is built to IEC 60947-2, the IEC standard for low-voltage circuit breakers, covering rated operational voltage (up to 690 V class), breaking capacity, and protection performance.
Perform routine visual and thermal checks, tighten connections, exercise the opening/closing mechanism, and run primary/secondary injection tests to verify trip settings. Keep the trip-unit display and communication port functional, and log all tests for compliance records.
It combines intelligent protection, communication, and multiple certifications in a 630 A, 3P/4P, up-to-690 V breaker at a competitive cost, making it a cost-effective main-incoming solution. It avoids paying for unnecessary features while retaining the protection and monitoring critical for main switchgear.